7. During Job Paper Feed

This step is the time after Step 6 described above until job end.

Environment A-1

[*A]

User setting for each type of paper. Actual temperatures are listed.

[*B]

Adjust Temperature. There is a default setting for each thickness, and the default can be adjusted with the SP code.

[*C]

Adjust Temperature 2. There is a default setting for each thickness, and the default can be adjusted with the SP code.

The target temperature for the environment is calculated [*A] + [*B] + [*C]. However, [*B] and [*C] can be calculated in the SP mode.

  1. The paper temperature settings can be adjusted for each tray and paper of different thickness (Thick 1 to 8).
  2. An SP can be selected to adjust temperature [*A] (user tool paper settings) assigned for different paper thickness beforehand (allocated with Ricoh IMSS software).

Uncoated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-005

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-007

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Coated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-009

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-011

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Environment B-1

The target temperatures for the heating roller and pressure roller are applied as [*A] + [*B] + [*C]. However, [*B] “Adjust Temp. 1" the default (including cases where the default has been changed in the SP mode) is calculated:

(23oC – Machine Temp.)/23oC – 10oC)

Uncoated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-005

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-007

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Press R

[*A]

Thk 0

10°C

SP1-111-005

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-007

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Coated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-009

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-011

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Press R

[*A]

Thk 0

10°C

SP1-111-009

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-011

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Environment B-2

The target temperatures for the heating roller and pressure roller are applied as [*A] – [*B] + [*C]. However, [*B] “Adjust Temp. 1" the default (including cases where the default has been changed in the SP mode) is calculated:

Machine Temp. – 23oC/(32oC – 23C)

Uncoated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-006

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-008

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Press R

[*A]

Thk 0

10°C

SP1-111-006

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-008

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Coated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-010

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-012

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Press R

[*A]

Thk 0

10°C

SP1-111-010

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-012

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Environment C-1

The target temperatures for the heating roller and pressure roller are calculated as [*A] – [*B] + [*C].

Uncoated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-006

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-008

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Press R

[*A]

Thk 0

10°C

SP1-111-006

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-008

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Coated Paper

Roller

 

[*B]

Thk

Default

SP No..

Htg R

[*A]

Thk 0

10°C

SP1-111-010

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-012

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

Press R

[*A]

Thk 0

10°C

SP1-111-010

Thk 1

10°C

Thk 2

10°C

Thk 3

10°C

Thk 4

10°C

Thk 5

10°C

SP1-111-012

Thk 6

10°C

Thk 7

10°C

Thk 8

10°C

8. After Paper Passing

The target temperature is set for each roller depending on detected ambient temperature as described below. (See Step 3. Roller Rotation After Reload Temperature).

9 Lower Power Mode

Heating Roller Target Temperature

Model

Temperature

SP

Type a

155°C

SP1-107-005

Type b

160°C

Type c

75°C

Pressure Roller Target Temperature

Model

Temperature

SP

Type a

75°C

SP1-107-006

Type b

75°C

Type c

65°C

The power to the fusing motor switches off, and the pressure roller releases pressure on the hot roller.

Low Power Mode Recovery Time

Model

Recovery Time

Type a

36 sec.

Type b

36 sec.

Type c

85 sec.

The low power mode temperature is fixed in order to minimize the recovery time. However, the low power mode temperature for Type c is set lower, so more time is necessary for recovery.

10 Off/Sleep Modes