7. During Job Paper Feed
This step is the time after Step 6 described above until job end.
Environment A-1
[*A]  | User setting for each type of paper. Actual temperatures are listed.  | 
[*B]  | Adjust Temperature. There is a default setting for each thickness, and the default can be adjusted with the SP code.  | 
[*C]  | Adjust Temperature 2. There is a default setting for each thickness, and the default can be adjusted with the SP code.  | 
The target temperature for the environment is calculated [*A] + [*B] + [*C]. However, [*B] and [*C] can be calculated in the SP mode.
- The paper temperature settings can be adjusted for each tray and paper of different thickness (Thick 1 to 8).
 - An SP can be selected to adjust temperature [*A] (user tool paper settings) assigned for different paper thickness beforehand (allocated with Ricoh IMSS software).
 
Uncoated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-005  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-007  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Coated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-009  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-011  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Environment B-1
The target temperatures for the heating roller and pressure roller are applied as [*A] + [*B] + [*C]. However, [*B] “Adjust Temp. 1" the default (including cases where the default has been changed in the SP mode) is calculated:
(23oC – Machine Temp.)/23oC – 10oC)
Uncoated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-005  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-007  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Press R  | [*A]  | Thk 0  | 10°C  | SP1-111-005  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-007  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Coated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-009  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-011  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Press R  | [*A]  | Thk 0  | 10°C  | SP1-111-009  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-011  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Environment B-2
The target temperatures for the heating roller and pressure roller are applied as [*A] – [*B] + [*C]. However, [*B] “Adjust Temp. 1" the default (including cases where the default has been changed in the SP mode) is calculated:
Machine Temp. – 23oC/(32oC – 23C)
Uncoated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-006  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-008  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Press R  | [*A]  | Thk 0  | 10°C  | SP1-111-006  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-008  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Coated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-010  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-012  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Press R  | [*A]  | Thk 0  | 10°C  | SP1-111-010  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-012  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Environment C-1
The target temperatures for the heating roller and pressure roller are calculated as [*A] – [*B] + [*C].
Uncoated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-006  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-008  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Press R  | [*A]  | Thk 0  | 10°C  | SP1-111-006  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-008  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Coated Paper
Roller  | [*B]  | |||
Thk  | Default  | SP No..  | ||
Htg R  | [*A]  | Thk 0  | 10°C  | SP1-111-010  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-012  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
Press R  | [*A]  | Thk 0  | 10°C  | SP1-111-010  | 
Thk 1  | 10°C  | |||
Thk 2  | 10°C  | |||
Thk 3  | 10°C  | |||
Thk 4  | 10°C  | |||
Thk 5  | 10°C  | SP1-111-012  | ||
Thk 6  | 10°C  | |||
Thk 7  | 10°C  | |||
Thk 8  | 10°C  | |||
8. After Paper Passing
The target temperature is set for each roller depending on detected ambient temperature as described below. (See Step 3. Roller Rotation After Reload Temperature).
9 Lower Power Mode
Heating Roller Target Temperature
Model  | Temperature  | SP  | 
|---|---|---|
Type a  | 155°C  | SP1-107-005  | 
Type b  | 160°C  | |
Type c  | 75°C  | 
Pressure Roller Target Temperature
Model  | Temperature  | SP  | 
|---|---|---|
Type a  | 75°C  | SP1-107-006  | 
Type b  | 75°C  | |
Type c  | 65°C  | 
The power to the fusing motor switches off, and the pressure roller releases pressure on the hot roller.
Low Power Mode Recovery Time
Model  | Recovery Time  | 
|---|---|
Type a  | 36 sec.  | 
Type b  | 36 sec.  | 
Type c  | 85 sec.  | 
The low power mode temperature is fixed in order to minimize the recovery time. However, the low power mode temperature for Type c is set lower, so more time is necessary for recovery.
10 Off/Sleep Modes
The heating roller lamps, pressure roller lamp, and fusing motor are shut down, and the pressure roller remains up against the fusing belt.