7. During Job Paper Feed
This step is the time after Step 6 described above until job end.
Environment A-1
[*A] | User setting for each type of paper. Actual temperatures are listed. |
[*B] | Adjust Temperature. There is a default setting for each thickness, and the default can be adjusted with the SP code. |
[*C] | Adjust Temperature 2. There is a default setting for each thickness, and the default can be adjusted with the SP code. |
The target temperature for the environment is calculated [*A] + [*B] + [*C]. However, [*B] and [*C] can be calculated in the SP mode.
- The paper temperature settings can be adjusted for each tray and paper of different thickness (Thick 1 to 8).
- An SP can be selected to adjust temperature [*A] (user tool paper settings) assigned for different paper thickness beforehand (allocated with Ricoh IMSS software).
Uncoated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-005 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-007 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Coated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-009 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-011 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Environment B-1
The target temperatures for the heating roller and pressure roller are applied as [*A] + [*B] + [*C]. However, [*B] “Adjust Temp. 1" the default (including cases where the default has been changed in the SP mode) is calculated:
(23oC – Machine Temp.)/23oC – 10oC)
Uncoated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-005 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-007 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C | |||
Press R | [*A] | Thk 0 | 10°C | SP1-111-005 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-007 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Coated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-009 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-011 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C | |||
Press R | [*A] | Thk 0 | 10°C | SP1-111-009 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-011 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Environment B-2
The target temperatures for the heating roller and pressure roller are applied as [*A] – [*B] + [*C]. However, [*B] “Adjust Temp. 1" the default (including cases where the default has been changed in the SP mode) is calculated:
Machine Temp. – 23oC/(32oC – 23C)
Uncoated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-006 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-008 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C | |||
Press R | [*A] | Thk 0 | 10°C | SP1-111-006 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-008 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Coated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-010 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-012 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C | |||
Press R | [*A] | Thk 0 | 10°C | SP1-111-010 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-012 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Environment C-1
The target temperatures for the heating roller and pressure roller are calculated as [*A] – [*B] + [*C].
Uncoated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-006 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-008 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C | |||
Press R | [*A] | Thk 0 | 10°C | SP1-111-006 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-008 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
Coated Paper
Roller | [*B] | |||
Thk | Default | SP No.. | ||
Htg R | [*A] | Thk 0 | 10°C | SP1-111-010 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-012 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C | |||
Press R | [*A] | Thk 0 | 10°C | SP1-111-010 |
Thk 1 | 10°C | |||
Thk 2 | 10°C | |||
Thk 3 | 10°C | |||
Thk 4 | 10°C | |||
Thk 5 | 10°C | SP1-111-012 | ||
Thk 6 | 10°C | |||
Thk 7 | 10°C | |||
Thk 8 | 10°C |
8. After Paper Passing
The target temperature is set for each roller depending on detected ambient temperature as described below. (See Step 3. Roller Rotation After Reload Temperature).
9 Lower Power Mode
Heating Roller Target Temperature
Model | Temperature | SP |
---|---|---|
Type a | 155°C | SP1-107-005 |
Type b | 160°C | |
Type c | 75°C |
Pressure Roller Target Temperature
Model | Temperature | SP |
---|---|---|
Type a | 75°C | SP1-107-006 |
Type b | 75°C | |
Type c | 65°C |
The power to the fusing motor switches off, and the pressure roller releases pressure on the hot roller.
Low Power Mode Recovery Time
Model | Recovery Time |
---|---|
Type a | 36 sec. |
Type b | 36 sec. |
Type c | 85 sec. |
The low power mode temperature is fixed in order to minimize the recovery time. However, the low power mode temperature for Type c is set lower, so more time is necessary for recovery.
10 Off/Sleep Modes
The heating roller lamps, pressure roller lamp, and fusing motor are shut down, and the pressure roller remains up against the fusing belt.