Five sensors are used to detect original width when the skew correction sensor detects the leading edge of the original.
- The length is detected by three sensors under the original table, and one more sensor above the bottom plate.
 - The machine uses the readings of width sensors and the length sensors to determine the size of the original being fed.
 
1  | Original Length Sensor (A4 LEF, LT LEF)  | 
2  | Original Length Sensor (B5)  | 
3  | Original Length Sensor (A4)  | 
4  | Original Length Sensor (LG)  | 
5  | Original Width Sensor 5  | 
6  | Original Width Sensor 4  | 
7  | Original Width Sensor 3  | 
8  | Original Width Sensor 2  | 
9  | Original Width Sensor 1  | 
Size  | Width Sensor  | Length Sensor  | |||||||
1  | 2  | 3  | 4  | 5  | A4 LEF LT LEF  | B5  | A4  | LG  | |
A3(297×420)  | ON  | ON  | ON  | ON  | ON  | ON  | ON  | ON  | ON  | 
B4(257×364)  | ON  | ON  | ON  | -  | -  | ON  | ON  | ON  | ON  | 
A4 SEF (210x297)  | ON  | ON  | -  | -  | -  | ON  | ON  | ON  | -  | 
A4 LEF (297×210)  | ON  | ON  | ON  | ON  | ON  | -  | -  | -  | -  | 
B5 SEF (182×257)  | ON  | -  | -  | -  | -  | ON  | ON  | -  | -  | 
B5 LEF (257×182)  | ON  | ON  | ON:  | -  | -  | -  | -  | -  | -  | 
B6 SEF (128×182)  | -  | -  | -  | -  | -  | -  | -  | -  | -  | 
B6 LEF (182×128)  | ON  | -  | -  | -  | -  | -  | -  | -  | -  | 
11"×17" SEF (DLT)  | ON  | ON  | ON  | ON  | -  | ON  | ON  | ON  | ON  | 
11"×15"SEF  | ON  | ON  | ON  | ON  | -  | ON  | ON  | ON  | ON  | 
8 1/2"×11" SEF (LT)  | ON  | ON  | -  | -  | -  | ON  | ON  | -  | -  | 
11"×81/2" LEF (LT)  | ON  | ON  | ON  | ON  | -  | -  | -  | -  | -  | 
SP6016-001 can be used to choose size detection or either 11"x17" P or 11"x5"P,