Lens-shaped blurred images appear at 314 mm (12.4 inch) intervals.
Cause:
If the machine is left unattended for a long period in an environment where temperature and humidity are high, the drum surface can absorb moisture and prevent the application or quenching of electrostatic charge on the drum.
Solution:
- On the machine operation panel: Adjustment Settings for Skilled Operators > Maintenance > Photoconductor Refreshing. (SP2-810-013: OPC Refresh Control: Manual Execute)
Print the image. Is the problem resolved?
Yes
Finished!
No
Consult the product specialist.