1. Remove the EDRB bracket (x4). (Remove the EDRB Bracket)
  2. One screw of the fusing motor [A] is blocked by the collar of the pressure roller lift motor [B] (which must be removed).
  3. Remove the upper screws [A] of the pressure roller lift motor bracket (x2).
  4. Remove the lower screws [B] of the bracket (x2).
  5. Unhook the bracket at the upper left corner [A], and then remove the bracket with motor attached. (x1)
  6. Disconnect the top edge of the fusing motor drive board [A] (x2).
  7. Disconnect each corner of the fusing motor bracket [B] (x4).
  8. Unhook the bracket at the upper left corner [A], and then remove the bracket with motor attached (x1).
  9. Unfasten the motor (x4).
  10. Separate the motor and the bracket.
  11. Before re-installation, lubricate the fusing motor drive gear.