1. After re-assembling the machine, open the left and front doors.
  2. Turn the machine on.
  3. Enter the operator adjust mode.
  4. In the operator adjust mode, touch [0515 Reset Replaceable Parts Counter], and then reset the counter to zero.
  5. Leave the operator adjust mode

    • For Steps 3, 4, 5 you can enter the SP mode, open SP7622-018 to set the counter to zero, and then leave the SP mode.

  6. Close the left and right front doors.
  7. Process control executes automatically.
  8. After process control executes, the operation panel will display “Ready”.
    • If process control fails, you will see “Fail” appear on the operation panel, and then the machine will issue an SC code.
    • Do the procedure recommended to resolve the problem that triggered the SC code.
    • You must then execute SP3011-002 to execute process control manually because it will not execute again automatically.
  9. This completes the procedure.