1. Insert the positioning pin (scanner wire jig) into the hole by the scale to position the unit correctly at the longest vertical mark on the scale.
  2. At the front of the laser unit [A], fold the plastic strip [B] under itself so that it can be pulled easily out of the machine from the front. (This strip is attached to the toner shield glass which must be removed for cleaning.)

    • After the laser unit is replaced, SP2108-001 must be executed for the new laser unit.
    • This SP downloads the operation parameters for the laser unit (main scan registration, main scan magnification, shading, and bow skew adjustment).