SC700-01 | D | ADF: bottom plate motor error |
The bottom plate HP sensor could not be detect the plate leaving the home position after the bottom plate motor turned on and started to raise the plate, or it did not detect the plate after the motor lowered it. | ||
|
SC700-02 | D | ADF: original pickup operation error |
Even though the pickup motor is rotating clock-wise, the pickup roller home position sensor cannot detect the position of the pickup roller. | ||
|
SC700-04 | D | ADF: feed motor error |
An error was detected during motor operation. | ||
|
SC700-05 | D | ADF: Pull-out roller motor error |
An error was detected during motor operation. | ||
|
SC700-06 | D | ADF: transport motor error |
An error was detected during motor operation. | ||
|
SC700-07 | D | ADF: scan motor error |
An error was detected during motor operation. | ||
|
SC700-09 | D | ADF: exit motor error |
An error was detected during motor operation. | ||
|
SC701-02 | D | ADF: pick-up roller motor drive board error |
This SC code may be appear with an original jam alert. There was a problem with the board that controls the pick-up roller motor. | ||
|
SC702-04 | D | ADF: interlock switch error 1 |
There is a problem (short, etc.) with either the cover interlock switch or lift interlock switch (24V). | ||
|
SC702-05 | B | ADF: interlock switch error 2 |
There is a problem (short, etc.) with either the cover interlock switch or lift interlock switch (24V). | ||
|
SC703-01 | B | ADF: double-feed detection error |
An error signal was detected for the double-feed detection function. | ||
|
SC720-01 | D | Finisher: Communication error with downstream peripheral |
| ||
|