1. Remove the LCT connection cover [A] (x1).
  2. Remove the right cover [A] (x7).
  3. Open the harness clamps [A] (x3).
  4. Disconnect the USB connector [B] (x1).
  5. Open and remove the small ferrite core.
  6. Disconnect the remaining harnesses, and then pull them away (x2).
  7. Remove the operation panel arm cover [A] (x2).
  8. There are two large shoulder screws that hold the operation panel on the machine.

    To prevent and accident or personal injury, never loosen or remove these large shoulder screws.

  9. Remove the base hex screws (x3)
  10. Slide the arm forward until it stops.
  11. While holding the arm as shown [A], pull the harness out of the machine [B], and then remove the operation panel from the top of the machine.

Re-installation

  1. Before you re-attach the right cover, be sure to close the clamps, and to re-attach the ferrite core. (x3).

    To prevent noise interference, make sure that the ferrite core is re-attached correctly and securely fastened.