- Remove the LCT connection cover [A] (
x1).
 - Remove the right cover [A] (
x7).
 - Open the harness clamps [A] (
x3).
 - Disconnect the USB connector [B] (
x1).
 - Open and remove the small ferrite core.
 - Disconnect the remaining harnesses, and then pull them away (
x2).
 - Remove the operation panel arm cover [A] (
x2).
 There are two large shoulder screws that hold the operation panel on the machine.
To prevent and accident or personal injury, never loosen or remove these large shoulder screws.
- Remove the base hex screws (
x3)
 - Slide the arm forward until it stops.
 - While holding the arm as shown [A], pull the harness out of the machine [B], and then remove the operation panel from the top of the machine.
 
Re-installation
Before you re-attach the right cover, be sure to close the clamps, and to re-attach the ferrite core. (
x3).
To prevent noise interference, make sure that the ferrite core is re-attached correctly and securely fastened.