1. The heating roller thermostats are located on the right front side of the unit.
  2. Remove the thermostat and leaf screws [A] and [B] (x6).
  3. Remove the gold leaf [A], and then remove the center thermostat [B].
  4. Remove the front thermostat.

    • To prevent a fire, never attempt to reset a blown thermostat by manipulating the exposed edges of the black cover with a screwdriver, or by hitting it on a table.
    • A thermostat that has been reset manually could fail and cause a fire.
    • Always replace a blown thermostat with a new one.