- Remove the fusing unit. (Removing the Fusing Unit)
- Release D2 and then raise the separation unit.
Disconnect both ends of the pressure roller stripper cover (
x1,
x1).
- The rear screw [A] and front screw [B] are different and must be re-attached at the same locations.
- Remove the cover [A].
- Remove the rear anti-static brush bracket (
x1).
Remove the front anti-static brush bracket (
x1).
- These static brushes are installed to scavenge stray toner. The brackets are identical.
- Disconnect the sensor bracket (
x1).
- Disconnect the exit sensor [A] and the pressure roller paper sensor [B] (
x1).
- Disconnect both ends of the pressure roller stripper bracket [B] (
x2).
- Pull the stripper bracket away slightly from the unit, and then free the harnesses (
x2.
- Remove the pressure roller stripper bracket.
- Lay the bracket on a clean flat surface.