1. Remove the fusing unit. (Removing the Fusing Unit)
  2. Release D2 and then raise the separation unit.
  3. Disconnect both ends of the pressure roller stripper cover (x1, x1).

    • The rear screw [A] and front screw [B] are different and must be re-attached at the same locations.

  4. Remove the cover [A].
  5. Remove the rear anti-static brush bracket (x1).
  6. Remove the front anti-static brush bracket (x1).

    • These static brushes are installed to scavenge stray toner. The brackets are identical.

  7. Disconnect the sensor bracket (x1).
  8. Disconnect the exit sensor [A] and the pressure roller paper sensor [B] (x1).
  9. Disconnect both ends of the pressure roller stripper bracket [B] (x2).
  10. Pull the stripper bracket away slightly from the unit, and then free the harnesses (x2.
  11. Remove the pressure roller stripper bracket.