The density is uneven.
Solution:
The solution depends on the type of unevenness. Carry out the appropriate procedure from those in the following table:
(A) The density is uneven across the entire image.
The density from top to bottom is uneven. |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, do the procedure for uneven density from top to bottom. (Uneven Density from Top to Bottom)
|
The sides are fainter or denser. |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual . Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, consult the product specialist.
|
The top and bottom are fainter or denser. |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, consult the product specialist.
|
(B) The density is uneven in a part of the image.
The leading edge is fainter. |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, do correction for Fainter Leading Edge. (Fainter Leading Edge)
|
The trailing edge is fainter. |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, do correction for Fainter Trailing Edge. (Fainter Trailing Edge)
|
The center is fainter or denser |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, consult the product specialist.
|
Wavy unevenness |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, consult the product specialist.
|
(C) The density is uneven in the direction perpendicular to the paper feed direction at regular intervals.
Periodic vertical density fluctuation |  |
| - On the machine operation panel: Adjustment Settings for Skilled Operators > Image Quality > Adjust Image Density > Image Density Adjustment: Manual Execute. (SP3-011-002: Manual ProCon :Ex Density Adjustment)
- If the problem persists, do correction for Periodic Density Fluctuation. (Periodic Density Fluctuation)
|