SC816 | Energy save I/O subsystem error | GW | |
-00 | D | - | |
-01 | D | Sub system error | |
-02 | D | sysarch(LPUX_GET_PORT_INFO) error | |
-03 | D | STR shift reject | |
-04 | D | Write error generated by kernel communication driver | |
-05 | D | STR pre-shift processing error | |
-07 | D | sysarch(LPUX_GET_PORT_INFO) error | |
-08 | D | sysarch(LPUX_ENGINE_TIMERCTRL) error | |
-09 | D | sysarch(LPUX_RETURN_FACTOR_STR) error | |
-10 | D | sysarch(LPUX_GET_PORT_INFO) error | |
-11 | D | sysarch(LPUX_GET_PORT_INFO) error | |
-12 | D | sysarch(LPUX_GET_PORT_INFO) error | |
-13 | D | open() Error | |
-14 | D | Memory address setting error | |
-15 | D | open() Error | |
-16 | D | open() Error | |
-17 | D | open() Error | |
-18 | D | open() Error | |
-19 | D | Duplicate open () error | |
-20 | D | open() Error | |
-22 | D | Parameter error | |
-23 | D | read() Error | |
-24 | D | read() Error | |
-25 | D | write() Error | |
-26 | D | write() communication retry error | |
-27 | D | write() communication retry error | |
-28 | D | write() communication retry error | |
-29 | D | read() communication retry error | |
-30 | D | read() communication retry error | |
-35 | D | read() Error | |
-36 | D | Sub System Error | |
-37 | D | Sub System Error | |
-38 | D | Sub System Error | |
-39 | D | Sub System Error | |
-40 | D | Sub System Error | |
-41 | D | Sub System Error | |
-42 | D | Sub System Error | |
-43 | D | Sub System Error | |
-44 | D | Sub System Error | |
-45 | D | Sub System Error | |
-46 | D | Sub System Error | |
-47 | D | Sub System Error | |
-48 | D | Sub System Error | |
-49 | D | Sub System Error | |
-50 | D | Sub System Error | |
-51 | D | Sub System Error | |
-52 | D | Sub System Error | |
-53 | D | Sub System Error | |
-54 | D | Sub System Error | |
-55 | D | Sub System Error | |
-56 | D | Sub System Error | |
-57 | D | Sub System Error | |
-58 | D | Sub System Error | |
-59 | D | Sub System Error | |
-60 | D | Sub System Error | |
-61 | D | Sub System Error | |
-62 | D | Sub System Error | |
-63 | D | Sub System Error | |
-64 | D | Sub System Error | |
-65 | D | Sub System Error | |
-66 | D | Sub System Error | |
-67 | D | Sub System Error | |
-68 | D | Sub System Error | |
-69 | D | Sub System Error | |
-70 | D | Sub System Error | |
-71 | D | Sub System Error | |
-72 | D | Sub System Error | |
-73 | D | Sub System Error | |
-74 | D | Sub System Error | |
-75 | D | Sub System Error | |
-76 | D | Sub System Error | |
-77 | D | Sub System Error | |
-78 | D | Sub System Error | |
-79 | D | Sub System Error | |
-80 | D | Sub System Error | |
-81 | D | Sub System Error | |
-82 | D | Sub System Error | |
-83 | D | Sub System Error | |
-84 | D | Sub System Error | |
-85 | D | Sub System Error | |
-86 | D | Sub System Error | |
-87 | D | Sub System Error | |
-88 | D | Sub System Error | |
-89 | D | Sub System Error | |
-90 | D | Sub System Error | |
-91 | D | Sub System Error | |
-92 | D | Sub System Error | |
-93 | D | Sub System Error | |
-94 | D | Sub System Error | |
Low power I/O sub system detected an error | |||
| |||
|
SC819-00 | D | Kernel halt error | GW |
Compatibility error was detected in the operating system. | |||
A RAM overflow error occurred during processing due to:
| |||
|
SC840-00 | B | EEPROM error 1: EEPROM access |
During the I/O processing, a reading error occurred. The 3rd reading failure causes this SC code. | ||
| ||
|
SC841-00 | B | EEPROM error 2: EEPROM read/write error |
Mirrored data of the EEPROM is different from the original data in EEPROM. | ||
| ||
|
SC842-00 | B | NAND-Flash Update Verify Error Detected. | GW |
SCS write error (verify error) occurred at the Nand-Flash module when remote ROM or main ROM was updated. | |||
| |||
|
SC842-01 | B | Insufficient Nand-Flash blocks (threshold exceeded) | GW |
At startup, or when machine returned from low power mode, the Nand-Flash status was read and judged that the number of unusable blocks had exceeded threshold, and then SCS generated the SC code. | |||
| |||
|
SC842-02 | B | Number of Nand-Flash block deletions exceeded | GW |
At startup, or when the machined returned from low power mode, the Nand-Flash was read and judged that the number of deleted blocks had exceeded threshold, and then SCS generated this SC code. | |||
| |||
|
SC853-00 | B | Bluetooth device connection error | GW |
The Bluetooth device (USB type) was connected after the machine was powered on. | |||
| |||
|
SC854-00 | B | Bluetooth device removed | GW |
This error occurred when the Bluetooth device (USB type) was removed. | |||
| |||
|
SC855-01 | B | Wireless LAN card error: Driver attach failed | GW |
SC855-02 | B | Wireless LAN card error: Driver failed to initialize | GW |
An error was detected for the wireless LAN card (802.11). | |||
| |||
|
SC857-00 | B | USB I/F Error | GW |
USB I/F could not be used due to driver malfunction | |||
| |||
|
SC858-01 | A | Data encryption error: HDD key setting error | GW |
When the data encryption key was updated, data was converted but a serious error occurred. | |||
| |||
|
SC858-02 | A | Data encryption error: NVRAM read error | GW |
When the data encryption key was updated, data was converted but a serious error occurred. | |||
| |||
|
SC858-30 | A | Data encryption error: NVRAM before replace error | GW |
When the data encryption key was updated, data was converted but a serious error occurred. | |||
| |||
|
SC858-31 | A | Data encryption error: other error | GW |
When the data encryption key was updated, data was converted but a serious error occurred. | |||
| |||
|
SC859-01 | B | Data encryption error: HDD check error | GW |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. | |||
| |||
|
SC859-02 | B | Data encryption error: Power loss during data encryption | GW |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. | |||
Power loss occurred while the data encryption key was being updated. | |||
|
SC859-10 | B | Data encryption error: Data read command error | GW |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. | |||
| |||
|
SC860-00 to 23 | B | HDD startup error at power on | GW |
| |||
| |||
|
SC864-01 to 23 | D | HDD data CRC error | GW |
During HDD operation, the HDD cannot respond to an CRC error query. | |||
| |||
|
SC865-00 to 23 | D | HDD access error | |
An error occurred during HDD operation. | |||
| |||
|
SC866-00 | B | SD card error 1: Confirmation | GW |
The machine detected an electronic license error in the application on the SD card in the controller slot immediately after the machine was turned on. Note:
| |||
| |||
|
SC867-00 | D | SD card error 2: SD card removed | GW |
The SD card was removed while the machine is on. | |||
The SD card required to start an application was removed during startup.. | |||
|
SC867 -01 | D | SD card error 2: SD card removed | GW |
The SD card was removed while the machine is on. | |||
The SD card required to start an application was not in the SD card slot. | |||
|
SC867-02 | D | SD card error 2: SD card removed | GW |
The SD card was removed while the machine is on. | |||
The SD card required to start an application was removed during startup. | |||
|
SC868-00 | D | SD card error 3: SD card access | GW |
An error occurred while an SD card was in use. | |||
| |||
SD card that starts an application 1. Turn the main power off and check the SD card insertion status.
2. SD card for users
3. If the error persists even after replacing the SD card, replace the controller board. * Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer. |
SC868-01 | D | SD card error 3: SD card access | GW |
An error occurred while an SD card was in use. | |||
| |||
SD card that starts an application 1. Turn the main power off and check the SD card insertion status.
2. SD card for users
3. If the error persists even after replacing the SD card, replace the controller board. * Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer. |
SC868-02 | D | SD card error 3: SD card access | GW |
An error occurred while an SD card was in use. | |||
| |||
SD card that starts an application 1. Turn the main power off and check the SD card insertion status.
2. SD card for users
3. If the error persists even after replacing the SD card, replace the controller board. * Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer. |
SC870-00 | B | Address book data error | GW |
Temporary address book error (another error that does not apply to other errors listed below) | |||
|
SC870-01 | B | Address book data error | GW |
No media to hold the saved address book data at startup. | |||
|
SC870-02 | B | Address book data error | GW |
The setting that enables data encryption at startup did not find the required module (DESS). | |||
|
SC870-03 | B | Address book data error | GW |
At initialization failed to generate file required to save the address book data. | |||
|
SC870-04 | B | Address book data error | GW |
At initialization failed to generate file required to save destination data. | |||
|
SC870-05 | B | Address book data error | GW |
At initialization the file required to generate destination address data failed. | |||
|
SC870-06 | B | Address book data error | GW |
At initialization failed to generate file required for LDAP search. | |||
|
SC870-07 | B | Address book data error | GW |
At initialization failed to initialize entry information required by the system. | |||
|
SC870-08 | B | Address book data error | GW |
At initialization there was a setting on the HDD required by the system for entry, but the initialization of the area to hold the address book failed to initialize. | |||
|
SC870-09 | B | Address book data error | GW |
Mismatch error occurred in NVRAM device setting for the area where the information required to save the address book configuration is stored. | |||
|
SC870-10 | B | Address book data error | GW |
No directory created for storage of the address book data in SD/USB Flash ROM (device setting). | |||
To store address book on SD card:
To store address book to Flash memory, cycle the machine off/on. |
SC870-11 | B | Address book data error | GW |
Mismatch error occurred with address book items at startup | |||
|
SC870-20 to 50 | B | Address book data error | GW |
During startup or operation, the machine detected an error in address book data retrieval or setting. | |||
Address book information error | |||
|
SC870-51 to 53 | B | Address book data error | GW |
During startup or operation, the machine detected an error in address book data retrieval or setting. | |||
Data encryption setting error | |||
|
SC870-54 to 58 | B | Address book data error | GW |
During startup or operation, the machine detected an error in address book data retrieval or setting. | |||
Data encryption setting error | |||
|
SC870-59 | B | Address book data error | GW |
During startup or operation, the machine detected an error in address book data retrieval or setting. | |||
The system could not determine the setting for the administrator's right. If this information cannot be retrieved, the address book cannot be accessed and the machine issues this SC error. | |||
|
SC870-60 | B | Address book data error | GW |
Could not retrieve system administrator permission setting | |||
The address book data cannot be read from the HDD or SD card where it is stored, or the data read from the media is defective. | |||
| |||
|
SC872-00 | B | HDD mail receive data error | GW |
HDD error detected at power on. | |||
| |||
When you do the above, the following information will be initialized.
|
SC873-00 | B | HDD mail send data error | GW |
HDD error detected at power on. | |||
| |||
When you do the above, the following information will be initialized.
|
SC874-99 | D | Delete data area (other errors) | GW |
An error occurred while data was being erased on HDD or NVRAM. | |||
| |||
SC875-01 | D | Delete ALL data error: HDD check error (hddchack –i) | GW |
SC875-02 | D | Delete ALL data error:Data delete failure | GW |
During deletion of data from the HDD, and error was detected before HDD erase. | |||
| |||
|
SC876-01 | D | Log data error 1 | GW |
An error was detected when data was retrieved from the log at startup, or while the machine was operating. | |||
| |||
|
SC 876-02 | D | Log data error 2 | GW |
An error was detected when data was retrieved from the log at startup, or while the machine was operating. | |||
When the log encryption setting was enabled, the encryption module was not installed. | |||
|
SC876-03 | D | Log data error 3 | GW |
An error was detected when data was retrieved from the log at startup, or while the machine was operating. | |||
Invalid log encryption key due to defective NVRAM data. | |||
|
SC876-04 | D | Log data error 4 | GW |
An error was detected when data was retrieved from the log at startup, or while the machine was operating. | |||
| |||
|
SC876-05 | D | Log data error 5 | GW |
An error was detected when data was retrieved from the log at startup, or while the machine was operating. | |||
| |||
|
SC876-99 | D | Log data error 6 | GW |
An error was detected when data was retrieved from the log at startup, or while the machine was operating. | |||
| |||
|
If you cannot recover operation of the machine with the countermeasures described above, do this procedure:
- Remove the HDD.
- Execute SP5801-019.
- Turn the machine off.
- Re-install the HDD, and then turn to machine on.
- Execute SP5832-004 to format the HDD.
- Cycle the machine off/on.
Steps 1 to 7 should cancel the SC error. But this also erases the log and data encryption settings which must be entered again manually. - Open SP9730-002 and set it to "1" (ON).
- Open SP9730-003 and set it to "1" (ON).
- Open SP9730-004 and set it to "1" (ON).
- Cycle the machine off/on.
SC877-00 | B | HDD SD card delete error | GW |
Data overwrite (Zoffy) did not execute even though the machine is set for Zoffy. | |||
| |||
|
SC878-00 | D | TPM authentication error | GW |
TPM electronic recognition failure | |||
| |||
|
Trusted Platform Module
In computing, Trusted Platform Module (TPM) is both the name of a published specification detailing a secure crypto processor that can store cryptographic keys that protect information, as well as the general name of implementations of that specification, often called the "TPM chip" or "TPM Security Device" (as designated in certain Dell BIOS settings).
SC878-01 | D | USB flash error | GW |
There is a problem in the file system of the USB flash memory. | |||
| |||
|
SC878-02 | D | TPM error 1 | GW |
An error occurred in either TPM or the TPM driver | |||
| |||
|
SC878-03 | D | TCSD dffof | GW |
An error occurred in the TPM software stack. | |||
| |||
|
SC880-00 | B | File Format Converter (MLB) error |
A request to get access to the MLB is not answered within the specified time. | ||
| ||
|
SC881-01 | D | Management area error | GW |
| |||
| |||
|
SC899-00 | D | Software error |
An unknown software error occurred in the GW controller. | ||
For a hardware defect
For a software error
|