SC300-00  | D  | Charge corona wire voltage error 1  | 
Charge wire voltage fell below the prescribed value.  | ||
  | ||
  | 
SC301-00  | D  | Charge corona wire voltage error 2  | 
Charge wire voltage fell below the prescribed value.  | ||
  | ||
  | 
SC304-00  | D  | Charge grid voltage error  | 
Grid voltage dropped below the prescribed voltage.  | ||
  | ||
  | 
SC308-00  | D  | Charge wire cleaner position error  | 
Charge wire cleaning motor operation error, or wire cleaner motor HP sensor error.  | ||
  | ||
  | 
SC316-00  | C  | Quenching lamp error  | 
The potential sensor cannot detect a reading from the light reflected onto the drum by the LED.  | ||
  | ||
  | 
SC320-00  | D  | Development Bias Error  | 
Development bias has dropped lower than the prescribed voltage.  | ||
  | ||
  | 
SC325-00  | D  | Development motor error  | 
The machine detected an error on the drive board of the development motor. The drive board is permanently attached to the motor.  | ||
  | ||
  | 
SC332-10  | D  | Toner supply motor error  | 
A toner supply bottle has locked and is not rotating.  | ||
  | ||
  | 
SC336-01  | D  | Developer set error (K)  | 
The TD sensor control voltage (Vcnt = 4.3V) output (Vt) was less than 0.7V.  | ||
  | ||
  | 
SC348-01  | D  | Toner supply error  | 
Toner was not detected in the development unit, or the development unit augur is not operating correctly.  | ||
  | ||
  | 
SC360-01  | D  | TD sensor calibration error (K)  | 
When the TD sensor was initialized, the TD sensor output could not be adjusted within ±0.1V of target Vt.  | ||
  | ||
  | 
SC361-01  | D  | TD sensor output error 1: Vt above upper limit  | 
The TD sensor output (Vt) was greater than 4.7V (SP3210-1) 20 consecutive times.  | ||
  | ||
  | 
SC362-01  | D  | TD sensor output error 1: Vt below lower limit  | 
The TD sensor output (Vt) was less than 0.5V (SP3210-001) 10 consecutive times.  | ||
  | ||
  | 
SC370-00  | D  | ID sensor calibration error  | 
The ID sensor Vsg_reg could not be initialized to 4±0.5V.  | ||
  | ||
  | 
SC371-00  | D  | ID sensor output error: Background reflected output  | 
The output reflected from the surface of the drum was Vsg_reg < 0.5V.  | ||
  | ||
  | 
SC372-00  | C  | ID sensor LED current upper limit error  | 
ID sensor (PWM) value is greater than the threshold value set by SP3320-15 (Default: 0).  | ||
  | ||
  | 
SC373-01  | D  | ID sensor pattern density high error  | 
The density of the black reading in the ID sensor patterns created between pages (SP3300-1) is greater than the threshold value set by SP3301-21.  | ||
  | ||
  | 
SC374-01  | D  | ID sensor pattern density low error  | 
The density of the black reading in the ID sensor patterns created between pages (SP3300-1) was less than the threshold value set by SP3301-23, three times in succession.  | ||
  | ||
  | 
SC381-01  | D  | Potential sensor output high error  | 
The potential sensor reading of the unexposed surface of the drum was Vd (700) > -800V. The Vd detected for process control at the start of a continuous job was more than 700V  | ||
  | ||
  | 
SC382-01  | D  | Potential sensor output low error  | 
Potential sensor reading of the unexposed surface of the drum was Vd (700) < -500V. The Vd is checked by the potential sensor for process control at the beginning of long, continuous print jobs  | ||
  | ||
  | 
SC395-00  | D  | Drum motor error  | 
An error signal was detected on the drive board of the drum motor. (The motor driver board and motor are permanently attached.)  | ||
  | ||
  |