- Cut the cushion at the position [A] along the groove of the left top cover of the Vacuum Feed LCIT.
- Remove the screws on the left top cover (
x2).
- Slide the left top cover [A] in the direction of the blue arrow and remove it.
- Slide the center top cover [A] in the direction of the blue arrow and remove it (
x3).
Attach the cover plate [A] (provided with the Multi Bypass Attachment Kit) to the front edge (
x2: M4x8).
- The screws are also provided with the Multi Bypass Attachment Kit.
- Remove the tape from the sponge strip provided with the Multi Bypass Attachment Kit.
Attach the sponge strip [A] to the rear edge.
- Paste it from the left end so that there is no gap between the left end and the sponge strip, and no gap between the right end and the sponge strip.
Attach the bracket [A] and joint pins [B] (
x1: M4x6).
These are provided with the Multi Bypass Tray.- The fixing screw is also provided with the Multi Bypass Tray.
- Mount the Multi Bypass Tray on the Vacuum Feed LCIT (
x2: M4x6).
Align the holes at the front and rear of the Multi Bypass Tray with the joint pins on the Vacuum Feed LCIT.
- The bypass unit weighs 20 kg (44 lb.). You may need assistance to set the bypass unit on top of the Vacuum Feed LCIT.