1. Remove the heating roller fusing lamps. (Heating Roller Fusing Lamps)
  2. Open the upper unit.
  3. At the rear, remove the drive gear (x1).
  4. At the rear, use spreaders to disconnect the heating roller [A] (x1).
  5. Remove the heating roller bearing [A].
  6. At the front, use spreaders to disconnect the heating roller [A] (x1).
  7. Remove the heating roller bearing [A].
  8. At the rear, remove the crescent bracket [A] (x2).
  9. At the front, remove the crescent bracket [A] (x2).
  10. At the front, remove the hot roller knob [A] (x1).
  11. At the rear, use spreaders to disconnect the hot roller [A] (x1).
  12. At the front, disconnect the hot roller shaft [A] (x1).
  13. At the front, remove the square bracket [A] (x2).
  14. At the rear, remove the square bracket [B] (x2).
  15. Grip the metal brackets at both ends of the hot roller [A], and then lift out the belt with the heating roller and hot roller together inside the belt.
  16. Lay the belt with the rollers on a flat clean surface.
    • [A] Hot roller
    • [B] Heating roller
    • [C] Fusing belt
  17. Remove the bracket (and bearing) from each end of the hot roller.
  18. Pull the roller out of the fusing belt.
  19. Separate the brackets and bearings removed from the ends of the hot roller.
  20. Spin the races of the bearings and make sure that they rotate easily.
  21. Pull the heating roller out of the fusing belt.