There are nine broad categories of SP codes, identified by group numbers.
Group | Comment |
---|---|
SP1000 | Feed. Paper feed SP codes: Image position adjustment, roller operation speeds, target fusing temperatures, etc. |
SP2000 | Drum. Drum operation related SP codes: Magnification adjustments, test pattern printing, etc. |
SP3000 | Process. Process control related SP codes, TD sensor initialization, toner draining and fill, process control setting adjustments, process control interval settings, etc. |
SP4000 | Scanner. Scanning operation related SP codes: Main and sub scan magnification adjustments, scanner free run, test pattern printing, LDAP certification, machine security, PM alarm, time setting, memory clear, |
SP5000 | Mode. Machine operation related SP codes: Display settings, counter settings, input and output checks for main machine, service telephone number setting, NVRAM data upload and download, network settings, HDD formatting, IEE802.11 setup, USB setup, UCS setting, |
SP6000 | Peripherals. Peripheral (options) related SP codes for peripheral units (including ADF): Finisher performance settings (folding, stapling, etc.), input and output checks for peripheral units, etc. |
SP7000 | Data Logs. Data log related SP codes: Counters, machine and peripheral PM parts displays, clear PM counters after part replacement, jam detection by location display (original and paper), consumable usage displays (toner), |
SP8000 | @Remote. A standard set of counters used to log more detailed information about machine operation that can be monitored from a remote location (service center). |
SP9000 | DFU. These SP codes are for “Design and Factory Use” only. These are used by designers for troubleshooting and machine testing and should never be used in the field by service technicians without specific instructions from design centers. |
The following notations are used in the SP mode tables.
Notation | What it means |
---|---|
[range/step] | Example: [–9 to +9/0.1 mm] The default setting can be adjusted in 0.1 mm steps in the range ±9. Note: The default setting for each SP mode is shown on the screen in the "Initial" box immediately below the entry box. |
DFU | Denotes "Design or Factory Use". Do not change this value. |
Japan Only | The feature or item is for Japan only. Do not change this value. |
LEF | Long Edge Feed |