You must reset the developer counter before you do this procedure. You will not be able to fill until the counter has been reset.

 

  1. Make sure that the front doors are still open, and then turn the machine on.
  2. Shake the new developer bottle up and down and then side to side about 3 times to loosen the developer.
  3. Attach the developer bottle to the machine. You will hear a click when it locks in place.
  4. Remove the bottle seal.
  5. Enter the SP mode and do SP3024-001 to start filling.

    • Filling requires about 60 sec. The machine will alert you with a message after filling is completed. If the operation fails, first make sure that you have removed the seal. Do SP3025-001 to check the result, and then repeat from Step 5.

  6. Remove the bottle.
  7. Do SP7622-003 to reset the counter.
  8. Close the doors.
  9. The machine automatically initializes the development unit TD sensor.
  10. After successful initialization of the TD sensor, the machine will automatically execute process control.

    • If a problem occurs, the machine will issue an SC code. Refer to the SC code tables, and then follow the procedure to correct the problem.
    • Next, do SP3030-001 to initialize the TD sensor.
    • Do SP3011-002 to force process control to execute manually.

  11. Do SP3012-001 to check the results of the process control execution.