SC101-01 | D | Exposure lamp error |
The write level peak did not reach the prescribed level when the white plate was scanned. White plate scanning is attempted three times to compensate for the possibility of noise on the serial path to the SBU. | ||
| ||
|
SC101-2 | D | Exposure lamp error |
LED error flag occurred. | ||
| ||
|
SC102-00 | D | Exposure lamp adjustment error |
After the prescribed number of adjustments, the write level peak exceeded the prescribed value when the white plate was scanned. | ||
| ||
|
SC120-00 | D | Scanner home position error 1 |
The scanner HP sensor did not go OFF :
| ||
| ||
|
SC121-00 | D | Scanner home position error 2 |
The scanner HP sensor did not go ON :
| ||
| ||
|
SC141-00 | D | Black level adjustment error |
The black level did not reach the prescribed level after AGC (Automatic Gain Control) adjustment done immediately after power on, or when leaving lower power mode. | ||
| ||
|
SC142-00 | D | White level detection error |
The white level did not reach the prescribed level after AGC (Automatic Gain Control) adjustment done immediately after power on, or when leaving lower power mode. | ||
| ||
|
SC144-00 | D | SBU Communication Error |
When the machine was switched on, or when the machine returned to full operation from the low power mode, the machine could not access the SBU register, or the SBU register values were abnormal. | ||
| ||
|
SC161-01 | D | IPU Error (LSYNC defective) |
At power on, or when the machine recovered from low power mode, the IPU executed self-diagnostics and detected an error (LSYNC). | ||
| ||
|
SC161-02 | D | IPU Error (Ri response error) |
An error occurred when the IPU was accessed. | ||
| ||
|
SC165-00 | D | Copy data security card error |
The optional copy data security card (also called “ICIB”) was not installed, even though the illegal copy function setting was done at initialization, or the ICIB was judged defective, the ICIB was judged defective when the machine was powered on or returned from low power mode. Note: This is the SD card that holds the firmware for the prohibit copy function that stops copying of currency, bank bonds, etc. | ||
| ||
|
SC185-00 | D | CIS communication error (ADF) |
The values read from the ASIC in the CIS register were different from the expected values, possibly due to a problem on the serial communication line between the CIS and ADF, or there was a problem with the initial value on the ASIC when the system was booted. Two attempts are made to obtain the correct values, and then this SC issues upon failure of the third attempt. | ||
| ||
|
SC186-00 | D | CIS error light source error |
There was a problem with the light source mounted in the CIS device at initialization. The average value in the area at the leading edge in the main scan direction was lower than the value prescribed for shading peak data at initialization and original feed. The dual array CIS LED may be defective, so there is a large difference between the averaged value in the area of the leading edge in the main scan direction and the average value in the area of the trailing edge. The first, second detections trigger initial/feed jam alerts, the third detection issues this SC code. | ||
| ||
|
SC187-00 | D | CIS black level check error |
Black level data not within range at black level creation when the black level was checked for the CIS device. The first, second detections trigger initial jam alerts, the third detection issues this SC code. | ||
| ||
|
SC188-00 | D | CIS white level check error |
The results of the reading of peak data values from the CIS device were abnormal and not within range for white level target, and confirmation of the shading data peak values failed. (The target values for white level adjustment are set with SP4785-001, SP4784-001, SP47846-001.) The first, second detections trigger initial jam alerts, the third detection issues this SC code. | ||
| ||
|
SC189-00 | D | CIS gray balance check error |
The results of the gray balance check with SP4705-002 was not on target and varied from Chart GS20. This SC is issued if there is an error on the first check. | ||
| ||
|
SC195-00 | D | Machine number code error |
An 11-digit code is required. | ||
| ||
|