SC101-01

D

Exposure lamp error

The write level peak did not reach the prescribed level when the white plate was scanned. White plate scanning is attempted three times to compensate for the possibility of noise on the serial path to the SBU.

  • LED defective
  • IDB (LED driver) defective
  • SBU defective
  • IPU defective
  • Power harness, signal harness defective
  • Condensation in scanner unit
  • Mirror, lens defective.
  • White plate missing or not installed correctly, plate defective, plate dirty
  • Cycle the machine off/on
  • Inspect and reset power harness, signal harness
  • Inspect and clean mirror, lenses
  • Inspect and clean white plate
  • Replace LED exposure lamp
  • Replace IDB
  • Replace SIO
  • Replace SBU
  • Replace IPU
  • Replace power harness, signal harnesses

SC101-2

D

Exposure lamp error

LED error flag occurred.

  • LED defective
  • IDB (LED driver) defective
  • Power harness, signal harness defective
  • Cycle the machine off/on
  • Inspect and reset power harness, signal harness
  • Replace LED exposure lamp
  • Replace IDB
  • Replace SIO
  • Replace power harness, signal harnesses

SC102-00

D

Exposure lamp adjustment error

After the prescribed number of adjustments, the write level peak exceeded the prescribed value when the white plate was scanned.

  • LED defective
  • IDB (LED driver) defective
  • SBU defective
  • IPU defective
  • Power harness, signal harness defective
  • Cycle the machine off/on
  • Inspect and reset power harness, signal harness
  • Replace IDB
  • Replace SIO
  • Replace SBU
  • Replace IPU
  • Replace LED exposure lamp driver (or SIO)
  • Replace power harness, signal harness

SC120-00

D

Scanner home position error 1

The scanner HP sensor did not go OFF :

  • During homing operation (power ON, leaving low power mode)
  • During auto adjustment (power ON, leaving low power mode)
  • During document, book scanning
  • SIO defective
  • Motor defective
  • HP sensor defective
  • Harness defective
  • Timing belt, pulley, wire, or carriage loose, defective
  • Replace SIO
  • Replace motor
  • Replace HP sensor
  • Replace harnesses
  • Inspect and replace timing belt, pulley, wire, or carriage

SC121-00

D

Scanner home position error 2

The scanner HP sensor did not go ON :

  • During homing operation
  • During auto adjustment
  • During document, book scanning
  • SIO defective
  • Motor defective
  • HP sensor defective
  • Harness defective
  • Timing belt, pulley, wire, or carriage loose, defective
  • Replace SIO
  • Replace motor
  • Replace HP sensor
  • Replace harnesses
  • Inspect and replace timing belt, pulley, wire, or carriage

SC141-00

D

Black level adjustment error

The black level did not reach the prescribed level after AGC (Automatic Gain Control) adjustment done immediately after power on, or when leaving lower power mode.

  • SBU defective
  • IPU defective
  • Power harness, signal harness defective
  • Cycle the machine off/on
  • Inspect and reset power harness, signal harness
  • Replace SBU
  • Replace IPU
  • Replace power harness, signal harness

SC142-00

D

White level detection error

The white level did not reach the prescribed level after AGC (Automatic Gain Control) adjustment done immediately after power on, or when leaving lower power mode.

  • SBU defective
  • LED defective
  • IDB (LED driver) defective
  • IPU defective
  • Power harness, signal harness defective
  • Scanner drive defective
  • Condensation in scanner unit
  • Mirror, lens defective.
  • White plate missing or not installed correctly, plate defective, plate dirty
  • Cycle the machine off/on
  • Inspect and reset power harness, signal harness
  • Inspect, clean, and reset mirrors, lenses
  • Inspect, clean, and reset white plate
  • Replace SBU
  • Replace LED exposure lamp
  • Replace IDB
  • Replace IPU
  • Replace SIO
  • Replace power harness, signal harness

SC144-00

D

SBU Communication Error

When the machine was switched on, or when the machine returned to full operation from the low power mode, the machine could not access the SBU register, or the SBU register values were abnormal.

  • SBU defective
  • BCU, IPU harness loose, disconnected, defective
  • Power harness, signal harness defective
  • Cycle the machine off/on
  • Inspect and reset power harness, signal harness
  • Replace SBU
  • Replace IPU
  • Replace BCU
  • Replace power harness, SBU-IPU harness, IPU-BCU harness

SC161-01

D

IPU Error (LSYNC defective)

At power on, or when the machine recovered from low power mode, the IPU executed self-diagnostics and detected an error (LSYNC).

  • IPU (BCU, CTL) board defective (ASIC-LEO connection defective, LSYNC defective, etc.)
  • SBU-IPU (or BCU) board defective, harness defective
  • Replace harnesses between SBU-IPU, or SBU-BCU
  • Replace IPU or BCU board

SC161-02

D

IPU Error (Ri response error)

An error occurred when the IPU was accessed.

  • IPU or BCU
  • Replace IPU board
  • Replace BCU board

SC165-00

D

Copy data security card error

The optional copy data security card (also called “ICIB”) was not installed, even though the illegal copy function setting was done at initialization, or the ICIB was judged defective, the ICIB was judged defective when the machine was powered on or returned from low power mode.

Note: This is the SD card that holds the firmware for the prohibit copy function that stops copying of currency, bank bonds, etc.

  • ICIB not installed, not installed correctly
  • ICIB option board defective
  • Inspect and reset ICIB option board installation
  • Replace ICIB option board

SC185-00

D

CIS communication error (ADF)

The values read from the ASIC in the CIS register were different from the expected values, possibly due to a problem on the serial communication line between the CIS and ADF, or there was a problem with the initial value on the ASIC when the system was booted. Two attempts are made to obtain the correct values, and then this SC issues upon failure of the third attempt.

  • Connector loose, broken, defection on the harness between ADF and CIS
  • CIS ASIC defective
  • CIS ASIC not booting
  • Inspect and reset power harness, harness between ADF and CIS controller
  • Replace CIS + CIPB
  • Replace ADF main control board
  • Replace power harness, signal harness

SC186-00

D

CIS error light source error

There was a problem with the light source mounted in the CIS device at initialization. The average value in the area at the leading edge in the main scan direction was lower than the value prescribed for shading peak data at initialization and original feed.

The dual array CIS LED may be defective, so there is a large difference between the averaged value in the area of the leading edge in the main scan direction and the average value in the area of the trailing edge. The first, second detections trigger initial/feed jam alerts, the third detection issues this SC code.

  • CIS defective
  • Communication error
  • Insufficient light
  • CIS white roller dirty, damaged, or installed incorrectly
  • Inspect and reset the power harness, harnesses between the CIS-ADF main board, and CIS-IPU
  • Replace CIS + CIPB
  • Inspect, clean, and reset CIS white roller
  • Replace CIS white roller
  • Replace power harness, signal harness
  • Replace ADF main board

SC187-00

D

CIS black level check error

Black level data not within range at black level creation when the black level was checked for the CIS device. The first, second detections trigger initial jam alerts, the third detection issues this SC code.

  • CIS device defective
  • Replace CIS + CIPB

SC188-00

D

CIS white level check error

The results of the reading of peak data values from the CIS device were abnormal and not within range for white level target, and confirmation of the shading data peak values failed. (The target values for white level adjustment are set with SP4785-001, SP4784-001, SP47846-001.) The first, second detections trigger initial jam alerts, the third detection issues this SC code.

  • CIS device defective
  • Communication error
  • White roller behind the CIS damaged, dirty, or not installed correctly.
  • Insufficient light
  • Inspect and reset power harness, CIS-ADF main board harness, CIS-IPU harness
  • Replace CIS + CIPB
  • Inspect and clean CIS white roller, check installation
  • Replace power harness, signal harness

SC189-00

D

CIS gray balance check error

The results of the gray balance check with SP4705-002 was not on target and varied from Chart GS20. This SC is issued if there is an error on the first check.

  • Adjustment chart defective (dirty, damaged)
  • CIS device defective
  • Replace adjustment chart

SC195-00

D

Machine number code error

An 11-digit code is required.

  • The entered 11-digit code does not match
  • Enter the correct 11-digit code