• The lubricant blade, lubricant bar, lubricant roller (brush roller), and lubricant roller coupling are replaced together.
  • The lubricant bar must be removed before the lubricant roller, and then re-installed after the lubrication roller.

  1. Remove the drum cleaning unit.
  2. Remove the drive gears.
  3. Disconnect the ends of the roller shaft:
    [A] Bushing (x1)
    [B] Coupling (x1)
  4. Remove the seal coupling.
  5. Remove the roller.

Re-installation

  1. Before reassembling the unit, apply a 1:1 mixture of yellow toner and setting powder to the brush roller.
  2. [A] shows the minimum amount that should be applied, and [B] the maximum amount.