Twelve new jam LEDs are provided on the front covers of the drawer. An LED lights if a jam occurs at its location. This makes it much easier to locate and remove sheets that jam in the paper path by manually rotating the jam removal knobs.

The 12 jam LEDs are behind four covers on the front of the machine.

At the present time (Oct. 2016) LEDs A1, B1, B2 and D1 in the table below are not functional. Their function will be enabled in the near future.

No.

Cover

LED

1

Exit unit

C2, D1, D6

2

Purge tray

E

3

Registration unit

B1, B2, B4, B5, C1

4

Vertical transport unit

A1, A2, A3

 

Exit Unit Cover: D1, D6, C2

There are three jam LEDs behind the exit unit cover.

Purge Tray Cover: E

There is one jam LED behind the purge tray cover.


Registration Unit Cover: C1, B5, B4, B2, B1

There are five jam LEDs behind the registration unit cover.

Vertical Path Cover: A2, A3, A1

There are three jam LEDs behind the vertical transport unit cover.

  • A1 is the only LED that is held in place by a bracket. This bracket must be removed first, in order to remove the LED (x2).