The paper feed path is extremely long when many peripheral units are installed. In such a long path, the cumulative effect of paper skew or deviation in side-to-side registration may require adjustment.
- Skew [A] occurs when the trailing edge of the paper rotates away from the direction of paper feed.
If side-to-side registration shift [B] occurs, the sheet remains straight but shifts left or right away from center of the paper path.
- Before adjusting skew manually, be sure to enter the SP mode and set SP1206 to "2" (OFF). This disables side-to-side registration in the main machine’s registration unit.
Scales
- Skew and side-to-side registration are checked with graduated scales (shown below) where paper exits the units.
- The scales are provided so that you can visually check and measure the amount of skew or deviation in side-to-side registration.
- A scale for detecting skew and checking side-to-side registration ("S-to-S") is provided on the following peripheral units.
- Correction for both skew and side-to-side registration are possible.
Name | Skew | S-to-S | Comment |
LCIT | --- | --- | Correction is done in the registration unit of the main machine. |
Other Peripheral Units | Yes | Yes | Correction for both skew and side-to-side registration are possible when the unit is attached to the upstream unit with the single bracket. |
Use either the rear scale or front scale, depending on the type of paper used in your area:
- Rear [A]: DLT SEF (LT LEF for Ring Binder)
- Front [B]: A3 SEF (A4 LEF for Ring Binder)
The illustrations show where the scale for each peripheral unit is located:
- [A]: DLT/ [B]: A3
The illustration shows the scale on the left side of the Booklet Finisher tray. The same scale is at approximately the same position (paper exit) for the following units:
- Multi Folding Unit: Proof Tray, or Left Exit
- Ring Binder: Left Exit
- High Capacity Stacker: Proof Tray
In the illustration below:
- The RED lines indicate the single-piece brackets where adjustments can be done to eliminate skew and to correct side-to-side registration.
The GREEN lines indicated 2-piece joint brackets where adjustment is not possible (between the finisher and trimmer unit).
Unit
Name
Comment
[1]
LCIT
[2]
Main Machine
[3]
Decurl Unit (inside main machine)
Inside main machine
[4]
Cover Interposer Tray
[5]
Multi Folding Unit
[6]
Ring Binder
[7]
High Capacity Stacker
[8]
Finisher
Either finisher
[9]
Trimmer Unit (Joint Brackets x2)
Joint Brackets x2
Note: The Trimmer Unit [9] does not have the single bracket for the upstream unit that allows side-to-side adjustment with shims (described below).
Here are some general rules for testing and adjusting for paper skew or a shift in side-to-side registration.
- After installation of each peripheral device, do some test prints and check for the presence of skew, and check that side-to-side registration is correct.
- When you detect a problem with skew or side-to-side registration, do the adjustment on the joint bracket attached to the peripheral unit upstream of the unit where the problem occurred.
- Side-to-side registration is corrected by shifting the upstream joint bracket left or right. (See the next procedure.)
- Skew is eliminated by inserting spacers (shims) under the rear or front end of the joint bracket. These attached by screws to the peripheral units before they leave the factory.