When the engine starts up just before printing, the drum bias is set by the drum potential sensor.

Image create conditions

SP3600-001 Process, Potential Control

 

0: Fixed

1: Auto

DC bias

SP2-201

SP3-611

Development DC bias

SP2-212

SP3-612

LD power

SP2-211

SP3-613

  • SP3-600-001 sets process control potential control. Default: 1 (Auto).
  • If SP3-600-001 is set to “0”, the conditions for each image creation can be set and controlled by individual SP codes.
  • When SP3-600-001 is set to “1”, the conditions for each image creation are automatically set and adjusted to optimize the results.
  • The results of process control execution can be displayed as a two-column code with SP3-012-001.