When the engine starts up just before printing, the drum bias is set by the drum potential sensor.
Image create conditions | SP3600-001 Process, Potential Control | |
---|---|---|
0: Fixed | 1: Auto | |
DC bias | SP2-201 | SP3-611 |
Development DC bias | SP2-212 | SP3-612 |
LD power | SP2-211 | SP3-613 |
- SP3-600-001 sets process control potential control. Default: 1 (Auto).
- If SP3-600-001 is set to “0”, the conditions for each image creation can be set and controlled by individual SP codes.
- When SP3-600-001 is set to “1”, the conditions for each image creation are automatically set and adjusted to optimize the results.
- The results of process control execution can be displayed as a two-column code with SP3-012-001.