1

Skew Correction Sensor

2

Separation Sensor

3

Exit Sensor

4

Registration Sensor

5

Skew Correction Sensor

6

Double-Feed Detection Sensors (Lower: emitter, Upper: receiver) (Option)

The six sensors listed above are used in jam detection. The readings of their output are used as described in the table below.

Code

Display

Jam Name

Jam Description

13

P

Separation sensor late jam

Leading edge did not arrive after paper feed motor started and operated long enough for 224 mm of feed.

14

P

Skew sensor late jam

Leading edge not detected within time for 46 mm of feed after detection by separation sensor.

15

P

Skew sensor late jam

Leading edge not detected after pull out started (grip motor) and enough time elapsed for 172 mm of feed.

16

P

Registration sensor late jam

Leading edge not detected after skew correction sensor detected leading edge and enough time elapsed for 96 mm of feed.

17

P

Exit sensor late jam

Leading edge not detected after registration sensor detected leading edge and enough time had elapsed for 130 mm of feed.

63

P

Separation sensor lag jam

This table shows how the amount of feed is calculated when the leading edge of the original is not detected after grip motor starts to pull out original.

Standard value: -35.3)×1.5

However, if the operator changes the original length setting, the new specified value will be taken as standard.

64

P

Skew sensor lag jam

Trailing edge was not detected after separation sensor has detected trailing edge and enough time had elapsed for 46 mm of feed.

65

P

Skew sensor lag jam

Trailing edge not detected after relay motor stopped and enough time had elapsed for 82 mm of feed.

66

P

Registration sensor lag jam

Trailing edge not detected after skew correction sensor detected trailing edge and enough time had elapsed for 93 mm of feed.

67

P

Exit sensor lag jam

Trailing edge not detected after registration sensor detected trailing edge and enough time has elapsed for 130 mm of feed.

99

P

Double-feed jam*1

Double-feed sensor pair (ultrasound) detected a single weaker than that expected for the original is use and signaled double-feed.

*1

Detected by the double-feed sensors after this option is installed.

Abnormality Detection

Errors that occur twice in succession are treated as jams, three times in succession as SC errors.

No.

Problem

Release

Cause

700-01

Bottom plate lift moor error

Cycle the machine off/on with main power switch

Bottom plate position sensor abnormal (output abnormal), Bottom plate HP sensor abnormal ), Bottom plate lift motor abnormal (not operating), ADF control board abnormal

700-02

Paper pickup operation abnormal

Cycle the machine off/on with main power switch

Pickup HP sensor abnormal (output abnormal), Pickup motor abnormal (not operating), ADF control board abnormal

700-04

Feed motor error

Cycle main power switch off/on

Feed motor defective, Harness disconnected, Harness broken or defective, Motor blocked

700-05

Transport motor error

Cycle main power switch off/on

Feed motor defective, Harness disconnected, Harness broken or defective, Motor blocked

700-06

Transport motor error

Cycle main power switch off/on

Feed motor defective, Harness disconnected, Harness broken or defective, Motor blocked

700-07

Scan motor error

Cycle main power switch off/on

Feed motor defective, Harness disconnected, Harness broken or defective, Motor blocked

700-09

Exit motor error

Cycle main power switch off/on

Feed motor defective, Harness disconnected, Harness broken or defective, Motor blocked

701-02

Pickup roller motor drive board error

Cycle main power switch off/on

Motor drive IC abnormal

703-01

Double-feed detection not operating*1

Replace sensors

Double-feed circuit or sensor defective, Harness disconnected, broken, defective

185-00

CIS communication error

Cycle main power switch off/on

Communication harness between ADF and CIS loose, broken, defective.

ASIC in CIS abnormal

ASIC boot in CIS abnormal

186-00

CIS light element abnormal

Cycle main power switch off/on

At power on

One or both connectors of CIS LED damaged

During original feed

Leads of CIS LED damaged

ADF main control board defective

187-00

CIS black level confirmation error

Cycle main power switch off/on

CIS device abnormal

188-00

CIS white level confirmation error

Cycle main power switch off/on

CIS device abnormal

CIS background white roller damaged, installed incorrectly

189-00

CIS gray balance adjustment error

Cycle main power switch off/on

CIS device abnormal

Adjustment chart damaged, dirty, deteriorated

*1