1. Remove the heating roller fusing lamps. (Heating Roller Fusing Lamps)
  2. Remove the hot roller, heating roller, and fusing belt. (Hot Roller, Heating Roller, Fusing Belt)
  3. Disconnect both ends of the pressure roller stripper bracket [A] (x2). (Removing the cover is not necessary.)
  4. Turn the stripper bracket [A] away from the pressure roller.
  5. Disconnect both ends of the side plate (x2).

    • At re-installation of this plate, the screw must be attached at the center hole [B]. This hole is the default position. The other off-set holes are used to adjust the height of the plate. For more details about this adjustment, see the “Troubleshooting” section.

  6. Remove the side plate.
  7. At the rear, disconnect the pressure roller fusing lamp [A] (x1).
  8. Remove the pressure roller lamp bracket [A] (x1).
  9. At the front, disconnect the pressure roller lamp [A] (x1).
  10. Remove the pressure roller lamp bracket [A] (x1).
  11. At the rear, pull out the pressure roller lamp.

    • Always handle the fusing lamps by holding them on the ends. Never touch the surface of a fusing lamp.

  12. Lay the lamp on a flat clean surface.
  13. Use spreaders to disconnect the rear end of the pressure roller [A] (x1).
  14. Above the rear end of the pressure roller, insert a small driver through the cut-out [A] and push the gear out.
  15. Remove gear [B].
  16. Disconnect the pressure roller holding bracket at the rear [A] (x2).
  17. Disconnect the pressure roller holding bracket at the front [B] (x2).
  18. Grip the holding brackets on each end of the pressure roller, lift straight up, and then remove the roller.
  19. Lay the roller on a flat clean surface.