Each peripheral unit for this machine has the same single-piece connection bracket shown below. This adjustment can be done for every unit on the connection bracket attached to the upstream unit

  1. Enter the SP mode and set SP1206 to "2" (OFF).
  2. Disconnect the peripheral unit from the upstream unit.
  3. On the joint bracket attached to the upstream unit, loosen screws , , , and .
  4. Remove the bracket [A] (x1), rotate it 90 degrees, and re-fasten the screw. Changing the position of this bracket aligns the oval cut-out horizontally and frees the joint bracket so it can slide from side to side.
  5. Look at the scale [B].
  6. Slide the bracket to the left or right and tighten the screw.
  7. If the deviation from center was toward the front, slide the bracket to the rear and tighten screw .
    -or-
    If the deviation from center was toward the rear, side the bracket to the front and tighten screw .
  8. Tighten screws , , and .
  9. Do another test run, so that you can check the results of the adjustment.
  10. When you are finished, enter the SP mode and re-set SP1206 to "1".