- Pull out the PCDU. (PCDU Removal)
- The vent filter is under the flat cover on the left.
- Disconnect the cover at [A] and [B] (
x2).
- Free the cover (
x4).
- Remove the cover.
Carefully, use the tip of a flat head screwdriver to free the filter [A] and then remove it. (See the note below.)
- Work carefully to avoid damaging the sponge seal.
Hold the filter over a waste bin and gently tap it with the tip of a screwdriver to remove loose developer.
- To avoid damaging the filter mesh, never use a vacuum cleaner to clean the filter.
- Before you re-install the filter, check the casing where the filter was removed:
- The area should be free of toner [A].
- There should be no excess toner as shown at [B].
- If you see excess toner, use the tip of a screwdriver to lightly tap the sides of the casing so that the excess will fall down into the unit.