1. Open the front drawer (Opening and Closing the Drawer)
  2. The invert junction gate solenoid is behind a plate on the left bottom edge of the front drawer.
  3. Remove the plate (x3).
  4. Remove the bracket (with solenoid attached) (x1, x1, x2).
  5. Disconnect the plunger (x1).
  6. Separate the solenoid from the bracket (x2, x2).