- Switch the machine off.
- Open the front doors.
- Before replacing the developer, you must clean the doctor blade and the development roller. (Cleaning Doctor Blade, Development Roller Cleaning)
- Set hole [A] of the toner bottle on the boss [B].
- Push the bottle in until you hear it click.
- With the front doors still open, turn the machine on.
Enter the SP mode and do SP3022-001 to start draining the developer.
- The developer requires about 150 sec. to drain completely.
- If the operation fails, the machine will alert you with a message. Do SP3023-001 to check the result, and then repeat from Step 3.
- The machine will alert you when the operation is finished.
- Switch the machine off. Remove the bottle, and then re-attach its seal to prevent spillage.
Remove the old development unit, and replace it with the new unit.
- Do not re-attach the front edge cover.