No.

Name

A

Exit Junction Gate

B

Exit JG Sensor

C

Exit Sensor

In straight-through output the paper leaves the fusing unit and then passes below the heat pipe.

  • When the exit/invert motor goes on, a cam depresses the pawl of the exit junction gate [A] and the paper passes through to the exit roller.
  • The exit JG sensor [B] in the exit path detects the arrival and passing of the paper.
  • The exit sensor [C] detects the leading edge and trailing edge of the paper as it exits the machine.