- Remove the front edge cover (
x3).
- Remove the charge corona unit. (PCDU Removal)
- Remove the front cover plate [A] (
x1).
- Disconnect the rear shield plate [B] (
x1).
- Slowly, remove the shield plate [A]. The tines of the plate are connected to the grid.
- Disconnect the grid [B] on the other end of the unit.
- Remove the grid.
- Turn the unit over, and then remove screw [A] at the front (
x1).
- Turn the unit over again, and then remove the cap [B].
- Turn the unit over and remove the ground plate [A] at the rear.
- Turn the unit over again, and then remove the cap [B].
- Pull straight up to release, and then remove the sponge bracket.
- At the front, disconnect the charge corona wires [A] (
x3).
At the rear [B], disconnect the wires from the posts.
- The charge corona wires are very brittle and break easily.
- Remove and handle them carefully.
- Avoid touching the wires with bare hands.
- Disconnect each wire from the rubber brackets [A] and [B].
- Remove each rubber bracket (x6).
- Each cleaning pad bracket is held in place by a snap ring.
- Pull off a snap ring to disconnect each cleaning pad bracket (
x3).
- Remove each cleaning pad bracket.
- When you install the unit in the machine, be sure to align the charge corona unit on its left plate and rail [A] before you push it into the machine [B].
After Charge Corona Wire Replacement
- After re-assembling the machine, open the left and front doors.
- Turn the machine on.
- Enter the SP mode and do SP7622-013 to 017 to reset the counters.