SC756-01

D

Ring Binder: Downstream device communication error

The ring binder did not detect the downstream device.

  • The interface cable connector disconnected/broken
  • Board on the ring binder or a downstream device defective
  • Replace the interface cable
  • Reconnect the connector
  • Replace the board on the ring binder or a downstream device

SC756-02

D

Ring Binder: Device connection order error

The ring binder did not detect the fixed device connection information command at the initial communication.

  • The interface cable connector disconnected/broken
  • Board on the ring binder or a downstream device defective
  • Replace the interface cable
  • Reconnect the connector
  • Replace the board on the ring binder or a downstream device

SC756-10

D

Ring Binder: Junction gate abnormal

  • Junction gate failed to move out of the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor could not detect the junction gate within the prescribed time (600 pulses). The first occurrence triggers a jam, the second an SC code.
  • Path JG motor (M201) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • JG HP sensor (S203) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-20

B

Ring Binder: Pre-punch side fence HP error

  • Thee sensor failed to detect that the component had moved out of the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor could not detect the component within the prescribed time (600 pulses). The first occurrence triggers a jam, the second an SC code.
  • Side jogger motor (M302) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Pre-punch jogger HP sensor (S302) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-21

B

Ring Binder: Pre-punch jogger roller HP sensor

  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (36 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor could not detect the component within the prescribed time (22 pulses). The first occurrence triggers a jam, the second an SC code.
  • Jog roller lift motor (M305) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Jog roller lift HP sensor defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-22

B

Ring Binder: Ring binder punch defective

  • Punch unit was not detected at unit initialization.
  • The HP sensor was still detected within 30 ms after the DC motor switched ON and made one revolution.
  • An encoder pulse was not detected within 5 ms after the DC motor switched ON and made one revolution at home position.
  • The HP sensor was not detected within 400 ms after the DC motor switched ON.
  • Punch motor (M304) defective
  • Connector loose, broken, defective
  • Motor overload
  • Punch HP sensor (S302) defective
  • Punch encoder sensor defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-30

B

Ring Binder: Paddle roller HP error

  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • Paddle roller lift motor (M603) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Paddle roller HP sensor defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-31

B

Ring Binder: Jogger fence 1 error

  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • Jog fence 1 motor (M604) defective
  • Connector loose, broken, defective
  • Motor overload
  • Side fence 1 HP sensor (S601) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-32

B

Ring Binder: Jogger fence 2 error

  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • Jog fence 2 motor (M606) defective
  • Connector loose, broken, defective
  • Motor overload
  • Side fence 2 HP sensor (S611) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-33

B

Ring Binder: Stack tamper HP error

  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • Stack tamper motor (M607) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Stack tamper HP sensor (S612) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-34

B

Ring Binder: Pre-bind jogger clamp HP error

  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • Spine clamp motor (M605) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • HP sensor (S603) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-40

B

Ring Binder: Binder unit run-out error

  
  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  
  • Run-out press roller motor (M610) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Run-out roller HP sensor (S614) defective
  
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-41

B

Ring Binder: Clamp thickness error

  
  • During jogging a 100-sheet stack was detected and the 50-sheet detect sensor (S606) went OFF. (1st detection signals a jam, 2nd detection issues this SC code.)
  • When the clamp moved to the open release position at initialization, the 50-sheet detect sensor went OFF.
  
  • 50-sheet detect sensor (S606) defective
  • Connector loose, broken, defective
  
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-42

B

Ring Binder: Alignment pin error

  
  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  
  • Alignment pin motor (M602) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Alignment pin HP sensor (S604) defective
  
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-43

B

Ring Binder: Pre-bind jogger shutter error

  
  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  
  • Shutter motor (M608) defective
  • Motor overloaded
  • Connector loose, broken, defective
  • Shutter HP sensor 1 (S605) defective
  
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-44

B

Ring Binder: 50/100 clamp adjustment error

  
  • When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
  
  • 50/100 clamp adjustment motor (M702) defective
  • Connector loose, broken, defective
  • Motor overload
  • Ring switch HP sensor (S706) defective
  • Ring switch timing sensor (S707) defective
  
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-45

B

Ring Binder: Timing sensor interval error

  

At initialization or ring binding, the ON or OFF time of the timing sensor exceeded 1500 ms (1st detection signals a jam, 2nd detection issues this SC code)

  
  • Clamp unit motor (M701) defective
  • Connector loose, broken, defective
  • Motor overload
  • Bind timing sensor (S702) defective
  
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-46

B

Ring Binder: Clamp unit HP error

  
  • At initialization or during ring binding, the unit did not arrive at home position within the prescribed time (1500 ms) (1st detection triggers a jam alert, 2nd detection issues this SC code).
  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (1500 ms) (1st detection triggers a jam alert, 2nd detection issues this SC code).
  
  • Clamp unit motor (M701) defective
  • Connector loose, broken, defective
  • Motor overload
  • Clamp unit HP sensor (S701) defective
  
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-47

B

Ring Binder: Spine alignment error

During alignment a home position timeout (400 ms) occurred twice during movement of the tip of the alignment pin (2nd attempt was within an additional 400 ms).

  • Alignment pin motor (M602) defective
  • Connector loose, broken, defective
  • Alignment pin HP sensor (S604) defective
  • Alignment pin up sensor (S610) defective
  • Jog mechanism defective
  • Punch defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-48

B

Ring Binder: Binder unit not detected

Binder unit was not detected at initialization before operation.

  • Connector loose, broken, defective
  • Drawer connector defective
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-50

B

Ring Binder: Output belt rotation error

  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (800 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor could not detect the component within the prescribed time (2300 pulses). The first occurrence triggers a jam, the second an SC code.
  • Output belt rotation motor (M403) defective
  • Connector loose, broken, defective
  • Motor overload
  • Output belt rotation HP sensor (S403) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-51

B

Ring Binder: Output belt 1 HP error

  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (200 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor could not detect the component within the prescribed time (2125 pulses). The first occurrence triggers a jam, the second an SC code.
  • Output belt 1 motor (M401) defective
  • Connector loose, broken, defective
  • Motor overload
  • Output belt 1 HP sensor (S401) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-52

B

Ring Binder: Output belt 2 HP error

  • The sensor failed to detect that the component had moved out of the home position within the prescribed time (200 pulses). The first occurrence triggers a jam, the second an SC code.
  • The sensor could not detect the component within the prescribed time (3130 pulses). The first occurrence triggers a jam, the second an SC code.
  • Output belt 2 motor (M402) defective
  • Connector loose, broken, defective
  • Motor overload
  • Output belt 2 HP sensor (S402) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-60

B

Ring Binder: Stack height error

The height of the stack increases until the stack height sensor goes ON. The sensor did not go ON within 6 sec. after the motor went ON (1st detection triggers a jam alert, 2nd detection issues this SC code).

  • Stacker motor (M501) defective
  • Connector loose, broken, defective
  • Motor overload
  • Stack height sensor 1 (S502) defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board

SC756-61

B

Ring Binder: Stacker error

  • At the start of stacking, or the end of the operation, even though the unit signaled stack full (stack up/down sensors went ON together), no stack was detected.
  • When stacking stopped, no stack was detected within 2 sec., even after the stack full alert. (1st detection triggers a jam, 2nd detection issues this SC code.)
  • Stacker HP sensor (S501) defective
  • Stack height sensor 1 (S502) defective
  • Stacker document sensor (S504) defective
  • Connector, loose, broken, defective
  • Replace the motor
  • Replace the sensor
  • Replace the connector
  • Reconnect the connector
  • Replace the board