SC756-01 | D | Ring Binder: Downstream device communication error |
The ring binder did not detect the downstream device. | ||
| ||
|
SC756-02 | D | Ring Binder: Device connection order error |
The ring binder did not detect the fixed device connection information command at the initial communication. | ||
| ||
|
SC756-10 | D | Ring Binder: Junction gate abnormal |
| ||
| ||
|
SC756-20 | B | Ring Binder: Pre-punch side fence HP error |
| ||
| ||
|
SC756-21 | B | Ring Binder: Pre-punch jogger roller HP sensor |
| ||
| ||
|
SC756-22 | B | Ring Binder: Ring binder punch defective |
| ||
| ||
|
SC756-30 | B | Ring Binder: Paddle roller HP error |
| ||
| ||
|
SC756-31 | B | Ring Binder: Jogger fence 1 error |
| ||
| ||
|
SC756-32 | B | Ring Binder: Jogger fence 2 error |
| ||
| ||
|
SC756-33 | B | Ring Binder: Stack tamper HP error |
| ||
| ||
|
SC756-34 | B | Ring Binder: Pre-bind jogger clamp HP error |
| ||
| ||
|
SC756-40 | B | Ring Binder: Binder unit run-out error |
| ||
| ||
|
SC756-41 | B | Ring Binder: Clamp thickness error |
| ||
| ||
|
SC756-42 | B | Ring Binder: Alignment pin error |
| ||
| ||
|
SC756-43 | B | Ring Binder: Pre-bind jogger shutter error |
| ||
| ||
|
SC756-44 | B | Ring Binder: 50/100 clamp adjustment error |
| ||
| ||
|
SC756-45 | B | Ring Binder: Timing sensor interval error |
At initialization or ring binding, the ON or OFF time of the timing sensor exceeded 1500 ms (1st detection signals a jam, 2nd detection issues this SC code) | ||
| ||
|
SC756-46 | B | Ring Binder: Clamp unit HP error |
| ||
| ||
|
SC756-47 | B | Ring Binder: Spine alignment error |
During alignment a home position timeout (400 ms) occurred twice during movement of the tip of the alignment pin (2nd attempt was within an additional 400 ms). | ||
| ||
|
SC756-48 | B | Ring Binder: Binder unit not detected |
Binder unit was not detected at initialization before operation. | ||
| ||
|
SC756-50 | B | Ring Binder: Output belt rotation error |
| ||
| ||
|
SC756-51 | B | Ring Binder: Output belt 1 HP error |
| ||
| ||
|
SC756-52 | B | Ring Binder: Output belt 2 HP error |
| ||
| ||
|
SC756-60 | B | Ring Binder: Stack height error |
The height of the stack increases until the stack height sensor goes ON. The sensor did not go ON within 6 sec. after the motor went ON (1st detection triggers a jam alert, 2nd detection issues this SC code). | ||
| ||
|
SC756-61 | B | Ring Binder: Stacker error |
| ||
| ||
|