SC756-01  | D  | Ring Binder: Downstream device communication error  | 
The ring binder did not detect the downstream device.  | ||
  | ||
  | 
SC756-02  | D  | Ring Binder: Device connection order error  | 
The ring binder did not detect the fixed device connection information command at the initial communication.  | ||
  | ||
  | 
SC756-10  | D  | Ring Binder: Junction gate abnormal  | 
  | ||
  | ||
  | 
SC756-20  | B  | Ring Binder: Pre-punch side fence HP error  | 
  | ||
  | ||
  | 
SC756-21  | B  | Ring Binder: Pre-punch jogger roller HP sensor  | 
  | ||
  | ||
  | 
SC756-22  | B  | Ring Binder: Ring binder punch defective  | 
  | ||
  | ||
  | 
SC756-30  | B  | Ring Binder: Paddle roller HP error  | 
  | ||
  | ||
  | 
SC756-31  | B  | Ring Binder: Jogger fence 1 error  | 
  | ||
  | ||
  | 
SC756-32  | B  | Ring Binder: Jogger fence 2 error  | 
  | ||
  | ||
  | 
SC756-33  | B  | Ring Binder: Stack tamper HP error  | 
  | ||
  | ||
  | 
SC756-34  | B  | Ring Binder: Pre-bind jogger clamp HP error  | 
  | ||
  | ||
  | 
SC756-40  | B  | Ring Binder: Binder unit run-out error  | 
  | ||
  | ||
  | 
SC756-41  | B  | Ring Binder: Clamp thickness error  | 
  | ||
  | ||
  | 
SC756-42  | B  | Ring Binder: Alignment pin error  | 
  | ||
  | ||
  | 
SC756-43  | B  | Ring Binder: Pre-bind jogger shutter error  | 
  | ||
  | ||
  | 
SC756-44  | B  | Ring Binder: 50/100 clamp adjustment error  | 
  | ||
  | ||
  | 
SC756-45  | B  | Ring Binder: Timing sensor interval error  | 
At initialization or ring binding, the ON or OFF time of the timing sensor exceeded 1500 ms (1st detection signals a jam, 2nd detection issues this SC code)  | ||
  | ||
  | 
SC756-46  | B  | Ring Binder: Clamp unit HP error  | 
  | ||
  | ||
  | 
SC756-47  | B  | Ring Binder: Spine alignment error  | 
During alignment a home position timeout (400 ms) occurred twice during movement of the tip of the alignment pin (2nd attempt was within an additional 400 ms).  | ||
  | ||
  | 
SC756-48  | B  | Ring Binder: Binder unit not detected  | 
Binder unit was not detected at initialization before operation.  | ||
  | ||
  | 
SC756-50  | B  | Ring Binder: Output belt rotation error  | 
  | ||
  | ||
  | 
SC756-51  | B  | Ring Binder: Output belt 1 HP error  | 
  | ||
  | ||
  | 
SC756-52  | B  | Ring Binder: Output belt 2 HP error  | 
  | ||
  | ||
  | 
SC756-60  | B  | Ring Binder: Stack height error  | 
The height of the stack increases until the stack height sensor goes ON. The sensor did not go ON within 6 sec. after the motor went ON (1st detection triggers a jam alert, 2nd detection issues this SC code).  | ||
  | ||
  | 
SC756-61  | B  | Ring Binder: Stacker error  | 
  | ||
  | ||
  |