Code  | Result Name  | Meaning  | 
|---|---|---|
0  | No execution  | SP default  | 
1  | Succeeded  | Finished  | 
2  | No developer output  | TD sensor reading was > 1.5V before developer replaced, indicating developer present  | 
3  | No developer present  | TD sensor reading was < 1.5V before developer replaced, indicating no developer present  | 
4  | Used toner full  | Used toner bottle is full  | 
5  | Development Motor lock  | Development motor is locked  | 
6  | Used toner motor lock  | The used toner bottle motor in the main machine, or the motor inside the toner bottle is locked  | 
9  | Forced end  | Forced end due to closing a door, switching power off  | 
Result display examples.
- [0] No execution (SP default)
 - [9] Developer installation after installation at the factory before shipping succeeded.
 - [4] Developer replacement after installation at factory before shipping returned used toner full
 - [1] Developer installation after installation at the factory before shipping succeeded.
 - [3] Developer installation after installation at the factory before shipping failed (no developer).
 - [1] Next execution succeeded
 
- Whenever an SC (Service Call) error occurs, refer to the SC code tables in the "Troubleshooting" section of the Service Manual.