Code | Result Name | Meaning |
---|---|---|
0 | No execution | SP default |
1 | Succeeded | Finished |
2 | No developer output | TD sensor reading was > 1.5V before developer replaced, indicating developer present |
3 | No developer present | TD sensor reading was < 1.5V before developer replaced, indicating no developer present |
4 | Used toner full | Used toner bottle is full |
5 | Development Motor lock | Development motor is locked |
6 | Used toner motor lock | The used toner bottle motor in the main machine, or the motor inside the toner bottle is locked |
9 | Forced end | Forced end due to closing a door, switching power off |
Result display examples.
- [0] No execution (SP default)
- [9] Developer installation after installation at the factory before shipping succeeded.
- [4] Developer replacement after installation at factory before shipping returned used toner full
- [1] Developer installation after installation at the factory before shipping succeeded.
- [3] Developer installation after installation at the factory before shipping failed (no developer).
- [1] Next execution succeeded
- Whenever an SC (Service Call) error occurs, refer to the SC code tables in the "Troubleshooting" section of the Service Manual.