After the main machine has been installed, you are ready to install the peripheral units selected for the installation.

In order to achieve optimal performance of the main machine with installed peripheral units, after the main machine and the peripheral units have been connected, you must check the version number of each installed peripheral unit to make sure that the most recent firmware is installed.

If the version number is not equal to or higher that the version numbers in the list below, you must download the correct version and install it for the peripheral.

Do this procedure after you have finished the installation of the main machine and the peripheral units.

  1. Make sure that the machine power cable is connected to the power source and that all the peripherals I/F cables are connected.
  2. If the peripheral has an independent power cable, make sure that the cable is connected to an independent power source.
  3. Turn the machine on.
  4. Go into the SP mode.
  5. Open SP7801.
  6. Check the version number of each peripheral unit against the list below.
  7. If the displayed version number is equal to or higher that the version number in the list, you are finished.
  8. If the displayed number is less than the version number in the list, you must download the correct version of the firmware for the peripheral unit, and then install it.

     

    PeripheralFirmwareVersion

    ADF

    ADF_SINAI_B

    01.110:05

    LCIT RT5080

    LCT_SIBERIA_G

    01.030:05

    LCIT RT5080 (*1)

    LCT2_SIBERIA_G

    01.030:05

    LCIT RT5070

    LCT_ALASKA-E

    01.020:05

    Vacuum Feed LCIT RT5100

    LCT1_LCIT5100

    01.040:06

    Vacuum Feed LCIT RT5100 *1

    LCT2_LCIT5100

    01.040:06

    Cover Interposer Tray CI5030

    Inserter_INSERTER

    01.060:03

    Finisher SR5050, Booklet Finisher SR5060

    BookletFinisher_SR506002.670.10

    Booklet Finisher SR5060

    BookletFinisher_SR5060

    02.670:10

    High Capacity Stacker SK5030

    Stacker_SK5030_1

    01.070:06

    High Capacity Stacker SK5030 *1

    Stacker_SK5030_2

    01.070:06

    Perfect Binder GB5010

    P-Binder_GB5010_B1

    01.200:11

    Perfect Binder GB5010

    P-Binder_GB5010_B2

    01.040:00

    Perfect Binder GB5010

    P-Binder_GB5010_B3

    00.050:00

    Perfect Binder GB5010

    P-Binder_GB5010_B4

    01.070:00

    Perfect Binder GB5010

    P-Binder_GB5010_B5

    01.020:00

    Ring Binder RB5020

    RingBinder_RB5020_B1

    01.500:06

    Ring Binder RB5020

    RingBinder_RB5020_B2

    01.000:03

    Trimmer Unit TR5040

    Trimmer_TR5040

    01.070:05

    RPIP Interface Box Type S3

    Fin_IFBox

    01.010:02

    *1 If the Vacuum Feed LCIT RT5100 and High Capacity Stacker SK5030 are installed in the same line, you must install Firmware Version 01.070:06 for the High Capacity Stacker.