Item

Details

Target Temperature & Humidity

23°C (73.4°F), 50% RH

Temperature range

10° to 32°C (50° to 90°F)

Perfect Binder: 15° to 30°C (59° to 86°F)

Humidity range

15 to 80% RH

Ambient illumination

Less than 1500 lux

Ventilation

Air turnover rate of more than 30m3/hr/person

Ambient dust

Less than 4.0 mg/m3

  • If the machine is installed in a location where the ambient temperature is more than 30°C (86°F), do not run a job longer than 2 hours.
  • Never turn the main power switch off immediately after a long print job. Leave the machine on so that the fans can expel the hot air from the machine and cool the electronic components.
  • If this machine is to be used in a location where both temperature and humidity are high, the tray heaters (options) should be installed and connected. For details, please refer to “Main Machine” in the “Installation” section.

  • Make sure that the power cord is rated 240V 20A (or 240V 15A) for the Pro8200EX main machine breaker switch.

  1. If the installation site has air-conditioners or heaters, put the machine in a location that agrees with these conditions:
    • Where there are no sudden temperature changes from low to high, or high to low.
    • Where the machine will not be directly exposed to cool air from an air conditioner in the summer.
    • Where the machine will not be directly exposed to reflected heat from a heater in the winter
  2. Do not put the machine where it will be exposed to corrosive gases like ammonia.
  3. Put the machine on a strong level surface. The front and rear of the machine must be level ±2.5 mm (0.1").
  4. Never put the machine where it can be subjected to strong vibration.
  5. Never connect the machine to a power source shared with other electrical devices.
  6. The machine can generate an electromagnetic field which can cause interference with radio or television reception.