Item  | Details  | 
|---|---|
Target Temperature & Humidity  | 23°C (73.4°F), 50% RH  | 
Temperature range  | 10° to 32°C (50° to 90°F) Perfect Binder: 15° to 30°C (59° to 86°F)  | 
Humidity range  | 15 to 80% RH  | 
Ambient illumination  | Less than 1500 lux  | 
Ventilation  | Air turnover rate of more than 30m3/hr/person  | 
Ambient dust  | Less than 4.0 mg/m3  | 
- If the machine is installed in a location where the ambient temperature is more than 30°C (86°F), do not run a job longer than 2 hours.
 - Never turn the main power switch off immediately after a long print job. Leave the machine on so that the fans can expel the hot air from the machine and cool the electronic components.
 - If this machine is to be used in a location where both temperature and humidity are high, the tray heaters (options) should be installed and connected. For details, please refer to “Main Machine” in the “Installation” section.
 
- Make sure that the power cord is rated 240V 20A (or 240V 15A) for the Pro8200EX main machine breaker switch.
 
- If the installation site has air-conditioners or heaters, put the machine in a location that agrees with these conditions:
- Where there are no sudden temperature changes from low to high, or high to low.
 - Where the machine will not be directly exposed to cool air from an air conditioner in the summer.
 - Where the machine will not be directly exposed to reflected heat from a heater in the winter
 
 - Do not put the machine where it will be exposed to corrosive gases like ammonia.
 - Put the machine on a strong level surface. The front and rear of the machine must be level ±2.5 mm (0.1").
 - Never put the machine where it can be subjected to strong vibration.
 - Never connect the machine to a power source shared with other electrical devices.
 - The machine can generate an electromagnetic field which can cause interference with radio or television reception.