Normally, you can use SP1002 to adjust the position of the images for paper feed from the LCITs. You can also change the paper feed position first, manually, by adjusting the support plate of the front cover of the tray, and then, second, adjusting the position of the image with SP1002.
- First, determine whether the paper stack needs to be moved to the front or the rear.
- Pull out the tray.
- There are three adjustment points on the left side [A] and right side [B] of the tray cover.
[1] These screws need to be loosened to release the cover. They do not need to be removed.
[2] This is the top adjustment grid (left and right).
[3] This is the bottom adjustment grid (left and right)
- In order to change the position of the front cover plate evenly, the adjustments must be done at all six points, two on the left side (top and bottom), two on the right side (top and bottom), and two screws loosened on the top.
First, loosen the screws on the top front edge of the tray.
- If you cannot see the screws, remove the front cover (
x4).
- If you cannot see the screws, remove the front cover (
- At each grid adjustment point, remove each screw [A]. This allows you to easily adjust the position of the cover so you can align the holes.
- Fasten the screw into hole [B] for the selected adjustment. Be sure to fasten the screw at the same hole at each adjustment point.
- The adjustment range is ±2 mm in 0.5 mm steps for each hole.
- In the example below, [A] is a full 2 mm adjustment to move the paper stack to the front.
- In the example below, [B] is a full 2 mm adjustment to move the paper stack to the rear.
- Tighten the screws on the top.
- Close the tray.
- Do some test prints, and then go into the SP mode and do the image adjustment for the tray with SP1002.