[1]

Main Unit

[2]

Vacuum Feed LCIT RT5100

[3]

Bridge Unit BU5010

[4]

LCIT RT5080

  1. On the right side of the bridge unit, attach joint pin [A] (x2 grooved) and joint pin [B] (x1 smooth). These joint pins are provided with the A3 LCT RT5080.
  2. Push the upstream A3 LCT close to the side of the Bridge Unit.
  3. Fasten the ground wire [A] from the A3 LCT to the Bridge Unit with the screw [B] provided with the A3 LCT (x1).

    • To avoid damage to this ground wire, before you separate these units, you must always remember to separate them slightly and then disconnect this ground wire before you separate the units completely.

  4. Open the front door of the upstream A3 LCT, and then remove the lock screw (x1).
  5. Release the lock bar [B] so that it slides freely from side to side.
  6. Slowly, push the upstream A3 LCT against the side of the Bridge Unit.
  7. With the front door of the A3 LCT open, fasten the lock bar above and the connection bracket below (x1, x1)
  8. Connect the I/F cable [A] of the upstream A3 LCT to the Bridge Unit.