Always follow this procedure before moving the LCT.
- To prevent damage to the ground wire (and the heater connector if the heater is installed), never attempt to move or change the position of the main machine with the LCT connected to the right side of the machine.
- At the rear, disconnect the unit I/F connector.
- Open the front door of the unit.
- Remove the screw (
x1).
- Pull the spring-loaded lock lever forward to separate it from the joint pins on the side of the main machine.
- Slowly, pull the LCT a short distance away from the machine.
- Disconnect the ground wire (
x1).
- Disconnect the heater connector, if the heaters (optional) have been installed (
x1).
- Pull the LCT away from the side of the main machine.