SC750-01 | D | Perfect Binder: Communication error with downstream peripheral |
| ||
| ||
|
SC750-10 | D | Perfect Binder: Master-to-slave communication error 1 |
Master control board could not communicate with the slave control board for over 5 sec. and issued the communication alarm. | ||
| ||
|
SC750-11 | D | Perfect Binder: Master-to-slave communication error 2 |
Slave control board could not communicate with the master control board for over 5 sec. and issued the communication alarm. | ||
| ||
|
SC750-12 | D | Perfect Binder: Master-to-relay board communication error |
| ||
| ||
|
SC750-13 | D | Perfect Binder: Slave-to-cutter control board communication error 1 |
Slave control board could not communicate with the cutter control board (it detected the communication alarm for over 5 sec.). | ||
| ||
|
SC750-14 | D | Perfect Binder: Slave-to-cutter control board communication error 2 |
Cutter control board could not communicate with the slave control board and detected the communication alarm for over 5 sec. | ||
| ||
|
SC750-15 | D | Perfect Binder: Master EEPROM Read Error |
Data written to the EEPROM does not match data read from the EEPROM | ||
| ||
|
SC750-16 | D | Perfect Binder: Master EEPROM write error |
When data was written to the EEPROM, the EEPROM signaled that it was busy for longer than 25 ms and did not recover. | ||
| ||
|
SC750-17 | D | Perfect Binder: Master-to-inserter initial communication error |
After the ConfigSet (parallel signal) went ON while the inserter connection status was being checked, the initialization did not end successfully within 5 sec. | ||
| ||
|
SC750-18 | D | Perfect Binder: Master-to-Inserter Board Communication Error |
No response to the specified command during the timeout. There was an overflow in memory where information required for paper feed is stored. (Master control board detection.) | ||
| ||
|
SC750-19 | D | Perfect Binder: Software matching error |
The IDs for the relay software of the master, slave, cutter, inserter devices do not match. | ||
| ||
|
SC750-20 | D | Perfect Binder: 24V Check Signal Error 1 |
The 24V1 monitor signal of the master control board did not go off even though the front door switch was closed. (Relay circuit failed to go ON.) | ||
| ||
|
SC750-21 | D | Perfect Binder: 24V Check Signal Error 2 |
Top cover switch open or the 24V2 monitoring signal of master controller lost power for more than 5 sec, regardless of the status of the front door L/RWS and top cover sensor. (Top cover sensor, or top cover switch is faulty.) | ||
| ||
|
SC750-22 | D | Perfect Binder: 24V Check Signal Error 3 |
The the 24V2 check signal of the slave control board failed to go OFF within 5 sec. even though the front door and top cover are closed. | ||
| ||
|
SC750-23 | D | Perfect Binder: 24V Check Signal Error 4 |
The 24V3 check signal of the slave control board failed to go OFF within 5 sec., regardless of the status of the front door (monitored by the master control board). | ||
| ||
|
SC750-24 | D | Perfect Binder: Power supply fan (right) lock error |
Right power supply fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try. | ||
| ||
|
SC750-25 | D | Perfect Binder: Power supply fan (center) lock error |
See SC750-24 | ||
| ||
|
SC750-26 | D | Perfect Binder: Left power supply fan lock error detected |
See SC750-24 | ||
| ||
|
SC750-27 | D | Perfect Binder: Spine plate fan (front) lock error |
Front spine plate fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try. | ||
| ||
|
SC750-28 | D | Perfect Binder: Spine plate lower fan (right) lock error |
See SC750-27 | ||
| ||
|
SC750-29 | D | Perfect Binder: Spine plate upper fan (front) lock error |
See SC750-27 | ||
| ||
|
SC750-30 | D | Perfect Binder: Spine plate upper fan (right) lock error |
See SC750-27 | ||
| ||
|
SC750-31 | D | Perfect Binder: Signature fan 2 (front) lock error |
Front signature fan 2 failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try. | ||
| ||
|
SC750-32 | D | Perfect Binder: Signature fan 2 (rear) lock error |
See SC750-31 | ||
| ||
|
SC750-33 | D | Perfect Binder: Signature fan 1 (front) lock error |
See SC750-31 | ||
| ||
|
SC750-34 | D | Perfect Binder: Signature fan 1 (rear) lock error |
See SC750-31 | ||
| ||
|
SC750-35 | D | Perfect Binder: Glue supply fan (high) lock error |
Glue supply (high) fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try. | ||
| ||
|
SC750-36 | D | Perfect Binder: Glue supply fan L lock error |
Glue supply L fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try. | ||
| ||
|
SC750-37 | D | Perfect Binder: Grip HP sensor lag error |
During operation of the grip unit the HP sensor did not OFF after grip unit moved 20 mm. | ||
| ||
|
SC750-38 | D | Perfect Binder: Grip HP sensor late error |
The HP sensor did not go ON after the grip unit released the signature and moved 76 mm. | ||
, overload, Sensor flag defective, connector broken defective | ||
|
SC750-39 | D | Perfect Binder: Grip end sensor lag error |
| ||
| ||
|
SC750-40 | D | Perfect Binder: Grip end sensor late error |
| ||
| ||
|
SC750-41 | D | Perfect Binder: Left trimming buffer HP sensor lag error |
The left trimmings buffer HP sensor did not go OFF within 3 sec. after the trimmings buffer moved away from the sensor. | ||
, Left trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings | ||
|
SC750-42 | D | Perfect Binder: Trimming buffer HP sensor late error |
The left trimmings buffer HP sensor did not go OFF within 5 sec. after the trimmings buffer moved toward the sensor. | ||
Trimmings buffer motor defective, Left trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings | ||
|
SC750-43 | D | Perfect Binder: Right trimming buffer HP sensor lag error |
The right trimmings buffer HP sensor did not go OFF within 3 sec. after the trimmings buffer moved away from the sensor. | ||
Trimmings buffer motor defective, Right trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings | ||
|
SC750-44 | D | Perfect Binder: Right trimming buffer HP sensor late error |
The right trimmings buffer HP sensor did not go OFF within 5 sec. after the trimmings buffer moved toward the sensor. | ||
Trimmings buffer motor defective, Right trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings | ||
|
SC750-45 | D | Perfect Binder: Trimmings buffer motor rotation error |
No encoder lock input received within 50 ms during operation. | ||
| ||
|
SC750-46 | D | Perfect Binder: Thrust plate operation error |
The thrust press plate sensor did not go OFF after the trimmings buffer moved to the left for 3 sec. (blocked by jammed trimming scraps). | ||
Trimmings buffer motor defective, Thrust plate sensor defective, overload, connector broken defective, buffer full of trimmings | ||
|
SC750-47 | D | Perfect Binder: Thrust plate retraction error |
The paper press plate sensor did not go ON after the trimmings buffer moved to the right for 3 sec. (blocked by jammed trimming scraps) | ||
Trimmings buffer motor defective, Thrust plate sensor defective, overload, connector broken defective, buffer full of trimmings. | ||
|
SC750-48 | D | Perfect Binder: Book collection buffer HP sensor error |
The book collection buffer HP sensor did not go OFF within the time prescribed for release of the book in the book buffer. | ||
Book buffer tray motor defective, Book collection buffer tray HP sensor defective, overload, connector broken defective, blocked by paper scraps | ||
|
SC750-49 | D | Perfect Binder: Book collection buffer tray HP sensor late error |
The book collection buffer HP sensor did not go off even after the book buffer tray moved for 3 sec. | ||
Book buffer tray motor defective, Book collection buffer tray HP sensor defective, overload, connector broken defective, blocked by paper scraps | ||
|
SC750-50 | D | Perfect Binder: Press HP sensor lag error |
During press plate operation during trimming, the edge press plate HP sensor did not OFF after it had time to move the prescribed distance. | ||
Edge press plate motor defective, Press HP sensor defective, overload, connector broken defective | ||
|
SC750-51 | D | Perfect Binder: Edge press plate late error |
| ||
| ||
|
SC750-52 | D | Perfect Binder: Press end sensor lag jam |
After the press plate released the signature and moved the prescribed distance, the press end sensor did not go OFF. | ||
Edge press plate motor defective, Press end sensor defective, overload, disconnected | ||
|
SC750-53 | D | Perfect Binder: Press end sensor late jam |
| ||
Edge press plate motor defective, Press end sensor defective, overload, disconnected, no data about book thickness received | ||
|
SC750-54 | D | Perfect Binder: Press limit sensor error |
Press limit sensor signaled ON. | ||
Press limit sensor signaled ON. | ||
|
SC750-55 | D | Perfect Binder: Slide HP sensor lag error |
When the slide was raised, the slide HP sensor did not go OFF after it moved 180 mm. | ||
Slide motor defective, slide HP sensor defective, overload, disconnected, book jam | ||
|
SC750-56 | D | Perfect Binder: Slide HP sensor late error |
The slide HP sensor did not go ON after the slide was lowered and had enough time to move 180 mm. | ||
Slide motor defective, slide HP sensor defective, overload, disconnected, book jam | ||
|
SC750-57 | D | Perfect Binder: Book rotation HP sensor (right) lag error |
| ||
Book rotation motor 1 (right) defective, Book rotation HP sensor (right) defective, overload, disconnected, book jam | ||
|
SC750-58 | D | Perfect Binder: Book rotation HP sensor (right) late error |
| ||
Book rotation motor 1 (right) defective, Book rotation HP sensor (right) defective, overload, disconnected, book jam | ||
|
SC750-59 | D | Perfect Binder: Book rotation HP sensor (left) lag error |
| ||
Book rotation motor 2 (left)defective, Book rotation HP sensor 2(left) defective, overload, disconnected, book jam | ||
|
SC750-60 | D | Perfect Binder: Book rotation HP sensor (left) late error |
| ||
Book rotation motor 2 (left)defective, book rotation HP 2 (left) sensor defective, overload, disconnected, book jam | ||
|
SC750-61 | D | Perfect Binder: Cutter front HP sensor lag error |
| ||
Cutter motor defective, Blade sensors 1, 2 defective, disconnected, overload | ||
|
SC750-62 | D | Perfect Binder: Cutter rear HP sensor late error |
When the blade was moved to the rear, it did not arrive at the home position after 122 mm of movement. | ||
Cutter motor defective, Blade sensors 1, 2 defective, disconnected, overload | ||
|
SC750-63 | D | Perfect Binder: Cutter rear HP sensor lag error |
| ||
Cutter motor defective, Blade sensors 1, 2 defective, disconnected, overload | ||
|
SC750-64 | D | Perfect Binder: Cutter front HP sensor lag error |
When the blade is moved to the front, the blade did not return to blade sensor 1 after enough time had elapsed for the blade to move 122 mm. | ||
Cutter motor defective, Blade sensors 1, 2 defective, disconnect, overload | ||
|
SC750-65 | D | Perfect Binder: Cut end late error |
| ||
Cutter motor defective, Blade sensors 1 defective, disconnected, overload. Blade is dull, not cutting efficiently. | ||
|
SC750-66 | D | Perfect Binder: Cut end lag error |
| ||
Cutter motor defective, Blade sensors 1 defective, disconnected, overload. Blade is dull, not cutting efficiently. | ||
|
SC750-67 | D | Perfect Binder: Trimmer limit sensor error |
Trimmer limit sensor signaled ON. | ||
Trimmer limit sensor defective Blade sensors 1, 2 defective , disconnect | ||
|
SC750-68 | D | Perfect Binder: Book lift tray HP sensor lag error |
| ||
Book lift tray motor defective, Book lift tray HP sensor defective, disconnect, overload | ||
|
SC750-69 | D | Perfect Binder: Book lift tray HP sensor late error |
While the book lift tray was being lowered, the book lift tray HP sensor did not go on after 1.5 sec. had elapsed. | ||
Book lift tray motor defective, Book lift tray HP sensor defective, disconnect, overload, Book jam, bundle drop | ||
|
SC750-70 | D | Perfect Binder: Book lift tray motor rotation error |
No encoder lock input received within 50 ms during operation. | ||
| ||
|
SC750-71 | D | Perfect Binder: Book output tray HP sensor lag error |
| ||
Book output belt motor defective, Book output tray HP sensor defected, disconnect, overload | ||
|
SC750-72 | D | Perfect Binder: Book out put tray HP sensor late error |
The book output tray HP sensor did not go ON within 3.5 sec. after it went OFF. | ||
Book output belt motor defective, Book output tray HP sensor defected, disconnect, overload | ||
|
SC750-73 | D | Perfect Binder: Blade cradle HP sensor lag error |
While the blade was retracting to the home position, the blade cradle sensor did not go OFF after enough time had elapsed for the blade to move 12 mm. | ||
Blade cradle motor defective, Blade cradle sensor defective, disconnect, overload | ||
|
SC750-74 | D | Perfect Binder: Blade cradle HP sensor late error |
While the bladed was being lowered, the blade cradle HP sensor did not go ON after enough time had elapsed for 21 mm of movement. | ||
Blade cradle motor defective, the blade cradle HP sensor defective, disconnect, overload, blade cradle or cutter physically jammed by obstacle | ||
|
SC750-75 | D | Perfect Binder: Book door lock error |
The book door sensor was detected OFF with the book door locked. | ||
Book door lock solenoid defective, Book door sensor defective, disconnect | ||
|
SC750-76 | D | Perfect Binder: Glue heater error |
The glue heater thermistor registered more that 200 degrees for more than 1 sec. | ||
| ||
|
SC750-77 | D | Perfect Binder: Electrical short in the gluing unit |
A temperature of less than 5 degrees was detected for 1 sec. or more than 10 sec. after power on.) However, if the thermistor detected less than 100 degrees after measuring temperature at start up, temperature is checked again after 50 sec. | ||
| ||
|
SC750-78 | D | Perfect Binder: Glue heater startup error 1 |
Glue temperature thermistor did not detect a temperature of 140 degrees within 200 sec. after it detected a temperature over 50 degrees. | ||
| ||
|
SC750-79 | D | Perfect Binder: Low temperature detection error |
After adjustment of the glue temperature, the glue temperature thermistor detected a temperature lower than 135 degrees for more than 10 sec. | ||
| ||
|
SC750-80 | D | Perfect Binder: High temperature error |
Thermistor detected abnormal high temperature. | ||
| ||
|
SC750-81 | D | Perfect Binder: Thermostat error |
Abnormal thermostat detection. | ||
| ||
|
SC750-82 | D | Perfect Binder: Glue level thermistor error 1 |
After glue warm-up completed, the glue level thermistor detected a temperature of over 170 degrees for more than10 sec. | ||
| ||
|
SC750-83 | D | Perfect Binder: Glue level thermistor error 2 |
After glue warm-up completed, the glue level thermistor detected a temperature less than 100 degrees for more than10 sec. | ||
| ||
|
SC750-84 | D | Perfect Binder: Thermistor disconnect error |
The glue abnormal temperature thermistor detected a temperature of less than 5 degrees for 1 sec., or more than 10 sec. after power on. However, if the thermistor detected less than 100 degrees after measuring temperature at start up, temperature is checked again after 50 sec. | ||
| ||
|
SC750-85 | D | Perfect Binder: Glue level thermistor disconnect error |
The AD value of the glue level thermistor was above 991 LSB for 10 sec. Temperature adjustment mode stops if glue level sensor detects the temperature remaining below 99 degrees for more than 10 sec. | ||
| ||
|
SC750-86 | D | Perfect Binder: Internal temperature thermostat error |
The A/D value of the internal temperature thermostat was detected above 80 degrees for 1 sec. | ||
Internal temperature thermistor defective, Slave board defective | ||
|
SC750-87 | D | Perfect Binder: Internal temperature thermostat disconnect error |
The A/D value of the internal temperature thermostat was detected below -20 degrees for 1 sec. | ||
Internal temperature thermistor defective, Slave board defective | ||
|
SC750-88 | D | Perfect Binder: Internal temperature thermostat error |
Temperature was detected above 10C three consecutive times (sampled every sec. for 1 min.). | ||
Internal temperature thermistor defective, Slave board defective | ||
|
SC750-89 | D | Perfect Binder: Glue heater startup error 2 |
The warm-up temperature was above the +-5C target for the glue vat temperature. (Not detected within 100 sec. after machine warm-up.) | ||
| ||
|
SC751-10 | D | Glue heater startup error 3 |
The warm-up temperature was below the +-5C target for the glue vat temperature. (Not detected within 100 sec. after machine warm-up.) | ||
| ||
|
SC751-11 | D | Perfect Binder: Glue heater startup error 4 |
At the end of temperature adjustment at power on, warm-up did not complete within 500 sec. The glue vat temperature did not reach the warm-up temperature within 500 sec. | ||
| ||
|
SC751-12 | D | Perfect Binder: Ambient temperature error |
Ambient temperature is not within the operational range: It was between 0°C and -20°C. | ||
| ||
|
SC751-13 | D | Perfect Binder: Glue low limit late error |
The level of the glue in the vat was detected below the low limit 4 times. | ||
| ||
|
SC751-14 | D | Perfect Binder: Glue high limit late error |
Without glue application, and with the glue level above the low limit, the glue level thermistor did not detect the the level of the glue at the high limit, even after 12 glue pellets were supplied. | ||
| ||
|
SC751-15 | D | Perfect Binder: Glue lowering level error |
Without glue supply, the level of the glue detected by the glue lever thermistor did not lower away from the high limit level, even after application of 25.42 g. | ||
| ||
|
SC751-16 | Perfect Binder: Glue level thermistor adjustment value error | |
| ||
| ||
|
SC751-17 | D | Perfect Binder: Timing sensor adjustment high value error |
The timing sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than 3.0 to 3.5V, even after timing sensor D/A output value was higher than 3.5V. | ||
| ||
|
SC751-18 | D | Perfect Binder: Cover registration sensor adjustment high value error |
The cover registration sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than 3.0 to 3.5V, even after cover registration sensor output value output was higher than 3.5V. | ||
| ||
|
SC751-19 | D | Perfect Binder: Cover horizontal registration sensor (S) adjustment high value error |
The cover horizontal registration sensor (S) A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor (S) D/A output value output was higher than 3.7V. | ||
| ||
|
SC751-20 | D | Perfect Binder: Cover horizontal registration sensor (L) adjustment high value error |
The cover horizontal registration sensor (L) A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover horizontal registration sensor (L) D/A output value output was higher than 3.7V. | ||
| ||
|
SC751-21 | D | Perfect Binder: Signature exit sensor adjustment high value error |
The signature exit sensor A/D input value was lower than 3.2 to 3.54V, the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor output value output was higher than 3.7V. | ||
| ||
|
SC751-22 | D | Perfect Binder: LE detect sensor adjustment high value error |
The leading edge detect sensor A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor A/D output value output was higher than 3.7V. | ||
| ||
|
SC751-23 | D | Perfect Binder: Entrance path sensor adjustment high value error |
When the entrance path sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the sensor D/A output was more than 3.3V. | ||
| ||
|
SC751-24 | D | Perfect Binder: Book registration sensor adjustment high value error |
When the book registration sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the sensor D/A output was more than 3.3V. | ||
| ||
|
SC751-25 | D | Perfect Binder: Timing sensor adjustment low value error |
The timing sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not enter the range 3.0 to 3.5V, even after timing sensor D/A output value was lower than 0.1V. | ||
| ||
|
SC751-26 | D | Perfect Binder: Cover registration sensor adjustment low value error |
The cover registration sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not enter the range 3.0 to 3.5V, even after cover registration sensor D/A output value output was lowered 0.1V. | ||
| ||
|
SC751-27 | D | Perfect Binder: Cover horizontal registration sensor (S) adjustment low value error |
The cover horizontal registration sensor (S) A/D input value was higher than 3.2 to 3.54V, and the A/D input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V. | ||
| ||
|
SC751-28 | D | Perfect Binder: Cover horizontal registration sensor (L) adjustment low value error |
The cover horizontal registration sensor (L) A/D input value was higher than 3.2 to 3.54V, and the A/D input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V. | ||
| ||
|
SC751-29 | D | Perfect Binder: Signature exit sensor adjustment low value error |
The signature exit sensor A/D input value was higher than 3.2 to 3.54V, the A/D input value did not enter the range 3.2 to 3.54V, even after cover registration sensor output value output was lowered 0.04V. | ||
| ||
|
SC751-30 | D | Perfect Binder: LE detect sensor adjustment low value error |
The LE detect sensor A/D input value was higher than 3.2 to 3.54V, and the sensor A/D input value did not enter the range 3.2 to 3.54V, even after the sensor output value was raised 0.04V. | ||
| ||
|
SC751-31 | D | Perfect Binder: Entrance path sensor adjustment low value error |
When the entrance path sensor was adjusted, the sensor A/D input was higher than 2.58 V, even after the sensor D/A output was lowered to 0V. | ||
| ||
|
SC751-32 | D | Perfect Binder: Book registration sensor adjustment low value error |
When the book registration sensor was adjusted, the sensor A/D input was more than 2.58 V, even after the sensor D/A output was less than 0V. | ||
| ||
|
SC751-33 | D | Perfect Binder: LE detect sensor late error |
The stack was late for gluing to the cover because there was no stack transport end sensor from the slave control board and there was no signal that the LE detect sensor had signaled to arrival of the stack. | ||
LE detect sensor connector loose, broken, defective
| ||
|
SC751-34 | D | Perfect Binder: Trim unit entrance sensor late error |
The stack was late arriving because the trim unit entrance sensor did not go ON even after a transport end signal was received. | ||
| ||
|
SC751-35 | D | Perfect Binder: Book registration sensor late error |
At the start of cutter registration, the book registration did not go ON. The stack could not be detected for fore edge cutting. | ||
| ||
|
SC751-36 | D | Perfect Binder: Signature exit sensor lag error |
When the power was turned on, the cover path was closed and the signature exit sensor detected paper present, but the LE detect sensor had detected no paper present. | ||
| ||
|
SC751-37 | D | Perfect Binder: Entrance path sensor late error |
During the automatic exit operation, the entrance path sensor could not detect any paper within 6860 ms after gluing and stack transport started. | ||
| ||
|
SC751-38 | D | Perfect Binder: Main grip late error |
There was no stack received from the sub grip unit; the main grip signature sensor detected no stack. | ||
| ||
|
SC751-39 | D | Perfect Binder: Trim unit entrance sensor lag error |
| ||
| ||
|
SC751-40 | D | Perfect Binder: Book registration sensor lag error |
Book registration sensor:
| ||
| ||
|
SC751-41 | D | Perfect Binder: Book arrival sensor lag error |
Not detected | ||
| ||
|
SC751-42 | D | Perfect Binder: Trimming jam error |
| ||
| ||
|
SC751-43 | D | Perfect Binder: Sub grip unit lag error |
When the sub grip unit was checked for the presence of paper, no paper could be detected even after opening the sub grip unit. | ||
| ||
|
SC751-44 | D | Perfect Binder: Main grip unit lag error |
| ||
| ||
|
SC751-45 | D | Perfect Binder: Signature thickness sensor minimum value error |
When the result of the signature thickness detection (A/D value) was adjusted, the minimum value (0 mm) was smaller than the A/D value of -30. | ||
| ||
|
SC751-46 | D | Perfect Binder: Signature thickness sensor maximum value error |
When the result of the signature thickness detection (A/D value) was adjusted, the maximum value (25mm) was smaller than the A/D value. | ||
| ||
|
SC751-47 | D | Perfect Binder: Signature thickness sensor value unstable error |
The signature thickness reading did not change, even after the main grip unit opened and closed. | ||
| ||
|
SC751-48 | D | Perfect Binder: Glue vat HP sensor late error |
| ||
| ||
|
SC751-49 | D | Perfect Binder: Glue vat HP sensor lag error |
The glue vat HP sensor did not go off when the glue vat moved to the front, even though the glue vat roller motor operated for 285 ms. The glue vat HP sensor was already ON when the glue vat moved from the front to the rear. | ||
| ||
|
SC751-50 | D | Perfect Binder: Glue vat roller motor error |
The glue vat roller rotation sensor could not detect rotation of the glue vat roller motor within 1200 ms of motor operation. | ||
| ||
|
SC751-51 | D | Perfect Binder: Glue roller HP sensor late error |
During glue supply, the glue roller HP sensor did not go ON, even though the glue roller motor was operating for 1000 ms. | ||
| ||
|
SC751-52 | D | Perfect Binder: Glue roller HP sensor lag error |
During glue supply, the glue roller HP sensor did not go OFF, even though the glue roller motor was operating for 2400 ms. | ||
| ||
|
SC751-53 | D | Perfect Binder: Spine fold HP sensor (L) late error |
| ||
| ||
|
SC751-54 | D | Perfect Binder: Spine fold HP sensor (L) lag error |
| ||
| ||
|
SC751-55 | D | Perfect Binder: Left spine fold plate close error |
In the operation of the left spine fold plate, the left spine close sensor did not go ON, even after the left spine fold plate motor was on for 5805 ms, equivalent to the plate moving 101.25 mm. When the spine fold plate moved from the closed to open position, the left spine close sensor was already OFF. | ||
| ||
|
SC751-56 | D | Perfect Binder: Left spine fold plate open error |
In the operation of the left spine fold plate, the left spine close sensor did not go OFFN, even after the left spine fold plate motor was on for 500 ms. When the spine fold plate moved from the open to closed position, the left spine close sensor was already ON. | ||
| ||
|
SC751-57 | D | Perfect Binder: Spine fold HP sensor (L) error |
The spine fold HP sensor (L) and spine fold close sensor (L) went ON at the same time. | ||
| ||
|
SC751-58 | D | Perfect Binder: Spine fold HP sensor (R) error |
| ||
| ||
|
SC751-59 | D | Perfect Binder: Spine fold HP sensor (R) lag error |
| ||
| ||
|
SC751-60 | D | Perfect Binder: Right spine fold plate close error |
The spine fold press sensor (right) did not go ON when the right fold plate was closing, even after the spine fold motor (right) was operating for 3225 ms (or enough time elapsed for the plate to travel 56.25mm). When the spine fold plate moved from the closed to open position, the spine fold press sensor (right) was already OFF. | ||
| ||
|
SC751-61 | D | Perfect Binder: Right spine fold plate open error |
| ||
| ||
|
SC751-62 | D | Perfect Binder: Spine fold HP sensor (R) error |
The spine fold HP sensor (R) and spine fold press sensor (R) went ON at the same time. | ||
| ||
|
SC751-63 | D | Perfect Binder: Spine fold plate open position late error |
At the start of the spine fold operation, the spine plate open sensor did not go ON, even after the spine plate motor operated for 900 ms (93.75 mm of feed). | ||
| ||
|
SC751-64 | D | Perfect Binder: Spine fold plate open position lag error |
At the start of the spine fold operation, the spine plate open sensor did not go OFF, even after the spine plate motor operated for 1350 ms (93.75 mm of feed). | ||
| ||
|
SC751-65 | D | Perfect Binder: Spine fold plate close position late error |
At the start of the spine fold operation, the spine plate close sensor did not go ON, even after the spine plate motor operated for 2250 ms (93.75 mm of feed). | ||
| ||
|
SC751-66 | D | Perfect Binder: Spine fold plate close position lag error |
At the start of the spine fold operation, the spine plate close sensor did not go OFF, even after the spine plate motor operated for 505 ms. | ||
| ||
|
SC751-67 | D | Perfect Binder: Front door lock error |
The front door lock release sensor did not go off, even though the door was locked. | ||
| ||
|
SC751-68 | D | Perfect Binder: Front door lock release error |
The front door lock release sensor did not go ON, even though the door was unlocked. | ||
| ||
|
SC751-69 | D | Perfect Binder: Front door force open error |
The front door was detected open, even though it was locked. | ||
| ||
|
SC751-70 | D | Perfect Binder: Switchback flapper HP sensor late error |
During the switchback flapper lift operation, the switchback flapper HP sensor did not go ON, even though the switchback flapper motor operated long enough for lifting through an arc of 50 degrees. | ||
| ||
|
SC751-71 | D | Perfect Binder: Switchback flapper HP sensor lag error |
During the switchback flapper lift operation, the switchback flapper HP sensor did not go OFF, even though the switchback flapper motor operated long enough for lowering through an arc of 150 degrees. | ||
| ||
|
SC751-72 | D | Perfect Binder: TE press lever HP sensor late error |
When the trailing edge press lever was released, the TE press lever HP sensor did not go ON, even though the TE press lever motor operated long enough to move the lever through and arc of 30 degrees. | ||
| ||
|
SC751-73 | D | Perfect Binder: TE press lever HP sensor lag error |
When the trailing edge press lever was released, the TE press lever HP sensor did not go OFF, even though the TE press lever motor operated long enough to move the lever through and arc of 20 degrees. | ||
| ||
|
SC751-74 | D | Perfect Binder: Jog fence front HP sensor late error |
The front jog fence HP sensor did not go ON, even thought the jog fence motor operated long enough for 60 mm of feed. | ||
| ||
|
SC751-75 | D | Perfect Binder: Jog fence front HP sensor lag jam |
While small-size paper was being jogged, the jog fence front HP sensor did not go OFF after the front jog fence motor operated long enough for 40 mm of feed. | ||
| ||
|
SC751-76 | D | Perfect Binder: Jog fence large HP sensor late error |
While large-size paper was being jogged, the front jog fence large HP sensor did not go ON, even though the jog fence front motor operated long enough for 70mm of feed. | ||
| ||
|
SC751-77 | D | Perfect Binder: Jog fence front large HP sensor lag error |
While large-size paper was being jogged, the jog fence front large HP sensor did not go OFF after the front jog fence motor operated long enough for 20 mm of feed. | ||
| ||
|
SC751-78 | D | Perfect Binder: Jog fence front HP sensor late error |
While jogging small-size paper, the right jog fence HP sensor did not go ON, even though the jog fence motor operated long enough for 60 mm of feed. | ||
| ||
|
SC751-79 | D | Perfect Binder: Jog fence right HP sensor lag jam |
While small-size paper was being jogged, the jog fence right HP sensor did not go OFF after the right jog fence motor operated long enough for 40 mm of feed. | ||
| ||
|
SC751-80 | D | Perfect Binder: Jog fence right large HP sensor late error |
While large-size paper was being jogged, the right jog fence large HP sensor did not go ON, even though the jog fence front motor operated long enough for 70mm of feed. | ||
| ||
|
SC751-81 | D | Perfect Binder: Jog fence right large HP sensor lag error |
While large-size paper was being jogged, the jog fence right large HP sensor did not go OFF after the right jog fence motor operated long enough for 20 mm of feed. | ||
| ||
|
SC751-82 | D | Perfect Binder: Switchback roller HP sensor late error |
During the switchback roller lift operation, the switchback roller HP sensor did not go ON, even though the switchback roller lift motor operated long enough for lifting through an arc of 40 degrees. | ||
| ||
|
SC751-83 | D | Perfect Binder: Switchback roller HP sensor lag error |
During the switchback roller lowering, the switchback roller HP sensor did not go OFF, even though the switchback roller lift motor operated long enough for lowering through an arc of 40 degrees. | ||
| ||
|
SC751-84 | D | Perfect Binder: Stacking tray lower limit late error |
When the stacking tray was lowered, the tray lower limit sensor did not go ON after the stacking tray lift motor had operated long enough for 90 mm of lift. | ||
| ||
|
SC751-85 | D | Perfect Binder: Stacking tray low limit lag error |
When the stacking tray was raised, the tray lower limit sensor did not go OFF after the stacking tray lift motor had operated long enough for 30mm of lift. | ||
| ||
|
SC751-86 | D | Perfect Binder: Paper detect sensor (front) detection error |
When the stacking tray was raised, the paper detect sensor (front) did not go ON, even after the stacking tray overflow sensor went ON and the stacking tray lift motor had operated for 30 mm of lift. | ||
| ||
|
SC751-87 | D | Perfect Binder: Paper detect sensor (front) no paper detection error |
When the stacking tray was lowered, the tray lower limit sensor did not go OFF after the stacking tray lift motor had operated long enough for 10mm of lowering. | ||
| ||
|
SC751-88 | D | Perfect Binder: Paper detect sensor (rear) paper detection error |
When the stacking tray was raised, the paper detect sensor (rear) did not go ON, even after the stacking tray overflow sensor went ON and the stacking tray lift motor had operated for 40 mm of lift. | ||
| ||
|
SC751-89 | D | Perfect Binder: Paper detect sensor (rear) no paper detection error |
When the stacking tray was lowered, the paper detect sensor (rear) did not go OFF after the stacking tray lift motor had operated long enough for 10mm of lowering. | ||
| ||
|