After new developer has been installed and SP3024-001 successfully executed, closing the front door automatically triggers initialization of the ID sensor and process control executes. The results can be confirmed with the following SP codes.

  • SP3025-001: Developer installation results display
  • SP3031-001: ID sensor initialization results display (only needed if there was a problem with developer installation and it was necessary to initialize the ID sensor with SP3030-001)
  • SP3012-001: Process control execution results display

  • After the ID initial settings for new developer, the value for TD sensor setting is set automatically for standard toner density.
  • This initial setting is done automatically only once for new developer. There is no SP code to initialize new developer automatically.
  • If an error occurs, or in the absence of specific instructions (an SP code for example), do not try to correct the problem with the SP codes described below.