A data sheet is provided with a new ADF unit.
- The sheet lists the following SP codes and the values that must be entered for each SP.
- These SP codes must be set after ADF replacement.
SP
Name
4-712-001
CIS GB Adj Value: R
4-713-001
CIS GB Adj Value: G
4-714-001
CIS GB Adj Value: B
After setting all the SP codes, print an SMC report so you can have a record of the new values in case you need to replace the NVRAM at a later time.