- Remove the drum cleaning unit (Drum Cleaning Unit)
 - With the drum cleaning unit pulled out, twist the knob counter-clockwise to unlock the drum.
 - Rotate the lock handle toward you to release the drum.
 - Pull the drum toward you at a slight angle to remove it.
 - Lay the drum on a flat clean surface.
 - Cover the drum with a piece of paper to protect it from the light.
 
Re-installation
Be sure to use the new drum knob fastening tool when you re-install the drum.
- If the knob is not fastened completely, this can cause the developer/toner mixture to collect on the magnetic roller and scratch the drum.
 - When you install the drum and fasten the drum knob with this tool, the drum cleaning unit should not be installed on the PCDU.
 - If the drum knob is loosened with the drum cleaning unit installed, be sure to remove the drum cleaning unit, and then fasten the knob.
 - Fastening the drum knob with the drum cleaning unit installed will cause the drum cleaning unit to apply pressure to the drum and narrow the gap at the front side.
 
- Press gently to insert the tabs into the knob.
 - Twist the drum knob clockwise until the tool runs idle.
 - Check the drum knob position. The groove [A] should be slightly to the right of the vertical reference line [B] in the photo.