Initiate Process Control

  1. Make sure that the machine is off.
  2. Open the left and right front doors of the machine.
  3. Switch the machine on.
  4. Enter the SP mode.
  5. Reset the PM part counter for the transfer roller to zero.
  6. Leave the SP mode.
  7. Close the left door and right door of the machine.
  8. Process control will start automatically.
  9. A message on the operation panel will tell you that process control has completed.
  10. Enter the SP mode.
  11. Do SP3012-001 to confirm that the process control execution completed successfully.
  12. Leave the SP mode.
  13. This completes the procedure.

If Process Control Fails

  1. If process control did not end successfully, the machine will issue an SC code.
  2. Correct the problem by following the steps recommended for releasing the SC code.
  3. After correcting the problem, process control will not execute automatically, so you will need to execute process control manually with SP3011-002.