1. Use spreaders to disconnect the bearing from the front end of the pressure roller [A] (x1).
  2. Pull the other bearing from the other end of the pressure roller (there is no fastener on the other bearing).
  3. Spin the races of the bearings and make sure that they rotate easily.
  4. If they do not turn easily, they must be replaced.
  5. At the bottom of the frame (near the front), inspect and clean the pressure roller thermistor [A] with a clean cloth.
  6. Always inspect and clean the pressure roller for contamination by grease before re-installing it.

    • Grease contamination can cause uneven heating on the surface of the roller and cause problems during fusing.

  7. Clean the entire surface of the roller with a dry cloth.
  8. Next, clean the entire surface with a cloth dampened with water (not alcohol).
  9. Finally, clean the entire surface again with a dry cloth.
  10. Use a small brush, or the tip of a small flat-tip screwdriver, etc. to apply Fluotribo MG grease to the inside surfaces of the pressure roller races.