The numbers correspond to the callouts in the illustration above.

Illustration No.No.1No.6No.8

Determine accum. temp. at warmup

No

Yes

No

Determine reload temp.?

No

Yes

No

Determine printing possible?

Yes

Yes

No

High temp. CPM down?*1

Yes

No

No

Hot roller idling?*2

No

No

No

Over temp. idling? *3

No

No

No

Illustration No.No.3No.2No.4
Determine accum. temp. at warmup

No

No

No

Determine reload temp.?

No

No

No

Determine printing possible?

No

No

No

High temp. CPM down?*1

No

No

Yes

Hot roller idling?*2

No

No

Yes

Over temp. idling? *3

No

No

No

 

In the table above:

1

Fusing Heat Thermistor (Rear)

2

Fusing Temperature NC Sensor (Heating Roller End)

3

Fusing Temperature NC Sensor (Heating Roller Center)

4

Fusing Temperature Thermistor (Hot Roller Center)

6

Fusing Temperature NC Sensor (Pressure Roller - Center)

8

Pressure Roller Thermistor

 

Determine accum. temp. at warmup

Yes

No

No

Determine reload temp.?

Yes

No

No

Determine printing possible?

Yes

Yes

No

High temp. CPM down?*1

No

Yes

Yes

Hot roller idling?*2

No

No

No

Over temp. idling? *3

Yes

Yes

Yes

In the table above:

Thermopile: Heating Roller Center

Thermopile: Front

Thermopile: Front Extended

*1

High Temperature CPM Down

 

If the fusing temperature exceeds the high temperature limit prescribed for these sensors, CPM down control changes the feed timing to create a wider interval between the sheets of paper feeding through the fusing unit.

*2

Hot Roller Idling

 

In Ready mode the hot roller does not rotate constantly to maintain a correct even temperature on the hot roller, but if the machine remains in Ready mode for a long period, the hot roller may cool. If Fusing Temperature Thermistor (Hot Roller Center), which monitors the center of the hot roller, detects that temperature has dropped below its prescribed limit, this triggers hot roller idling for the prescribed interval to bring the temperature up to operational level.

*3

Idling to Prevent Overheating

 

In the Ready mode, or when the machine returns from low power mode, if these sensors detect temperature above 215oC (default), the machine will not drive the hot roller and belt until temperature has fallen below the prescribed limit.

Total Time of Data: d (min.)

17506

 

Total Time of Data: d/60min. (Hour)

291.7667

 

Total Power Consumption of Data: e (min.)

656389