Twelve new Jam LEDs are provided on the left and right drawer covers. An LED lights if a jam occurs at its location. This makes it much easier to locate and remove sheets that jam in the paper path by manually rotating the jam removal knobs.
At the present time (Oct. 2016) LEDs A1, B1, B2 and D1 in the table below are not functional. Their function will be enabled in the near future.
No. | Cover | LED |
---|---|---|
1 | Exit unit | C2, D1, D6 |
2 | Purge tray | E |
3 | Registration unit | B1, B2, B4, B5, C1 |
4 | Vertical transport unit | A1, A2, A3 |
Each LED [A] is mounted on a peg opposite to a projection lens [B] mounted on the cover. When a jam occurs at its location, the LED lights and the light is magnified by the lens.
Each LED is mounted on a metal post on the front of the drawer unit. The LEDs are not connected to the front covers of the drawer unit, so their harnesses do not interfere with removal of the covers.