Before the scanner adjustment, do the Side-to-Side registration and image position adjustment.
Use A4/LT paper to make a temporary test chart.
Margin Position
- Put the temporary test chart on the SPDF. Then make a copy from one of the paper feed trays.
Check the registrations, and adjust as necessary with following SPs.
Standard: 0 ± 1.5 mm (Main scan), 0 ± 2.0 mm (Sub scan)SP No.
SP Name
Range
SP6-006-001
Side-to-Side Regist:Face
± 3.0 mm
SP6-006-002
Side-to-Side Regist:Back
± 2.0 mm
SP6-006-010
L-Edge Regist (1-Pass):Face
± 5.0 mm
SP6-006-011 L-Edge Regist (1-Pass):Back ± 5.0 mm SP6-006-014 T-Edge Erase (1-Pass):Face ± 5.0 mm SP6-006-015 T-Edge Erase (1-Pass):Back ± 5.0 mm
Magnification
- Place the temporary test chart on the SPDF and make a copy from one of the paper feed trays.
Check the magnification and adjust as necessary with following SP.
Standard: ± 1.0% or less
SP No.
Name
Range
SP6-017-001
SPDF Adjustment Magnification
± 5.0 %