Before the scanner adjustment, do the Side-to-Side registration and image position adjustment.

Use A4/LT paper to make a temporary test chart.

Margin Position
  1. Put the temporary test chart on the SPDF. Then make a copy from one of the paper feed trays.
  2. Check the registrations, and adjust as necessary with following SPs.
    Standard: 0 ± 1.5 mm (Main scan), 0 ± 2.0 mm (Sub scan)

    SP No.

    SP Name

    Range

    SP6-006-001

    Side-to-Side Regist:Face

    ± 3.0 mm

    SP6-006-002

    Side-to-Side Regist:Back

    ± 2.0 mm

    SP6-006-010

    L-Edge Regist (1-Pass):Face

    ± 5.0 mm

    SP6-006-011L-Edge Regist (1-Pass):Back± 5.0 mm
    SP6-006-014T-Edge Erase (1-Pass):Face± 5.0 mm
    SP6-006-015T-Edge Erase (1-Pass):Back± 5.0 mm
Magnification
  1. Place the temporary test chart on the SPDF and make a copy from one of the paper feed trays.
  2. Check the magnification and adjust as necessary with following SP.

    Standard: ± 1.0% or less

    SP No.

    Name

    Range

    SP6-017-001

    SPDF Adjustment Magnification

    ± 5.0 %