SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC230-00

D

FGATE ON error

The FGATE signal did not turn ON within the given time period after the writing process started.
  • Connection error between Engine and Controller

  • Engine board failure (Damaged ASIC)

Power cycle the machine to see if the error reoccurs. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power off/on after each step.
  1. Check the connection between the BCU and the controller board. (Printer model only)
  2. Replace the engine board (Printer: BCU, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC231-00

D

FGATE OFF error

The FGATE signal did not turn OFF within the given time period after the writing process ended.
  • Connection error between Engine and Controller

  • Engine board failure (Damaged ASIC)

Power cycle the machine to see if the error reoccurs. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power off/on after each step.
  1. Check the connection between the BCU and the controller board. (Printer model only)
  2. Replace the engine board (Printer: BCU, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC277-00

D

LEDA communication error

There was a communication error between the LED head array and the engine board when the machine was turned on or recovered from the Energy Save mode.

  • Loose connector, broken, defective or harness defective
  • LED head defective
  • Engine board (Printer: BCU, MF: SCB) defective
Power cycle the machine to see if the error reoccurs. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power off/on after each step.
  1. Check if the SC reoccurs by returning from energy saver mode.
  2. Reconnect the FFC connectors (LED head - engine board).
  3. Replace the FFC.
  4. Replace the LED head.
  5. Replace the engine board.
SC277-10DLEDA communication error (other)
Power supply to the LED head array is abnormal after the machine was turned on or recovered from the Energy Save mode.
  • Engine board (Printer: BCU, MF: SCB) defective
Power cycle the machine to see if the error reoccurs. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power off/on after each step.
  1. Check if the SC reoccurs by returning from energy saver mode.
  2. Check if the SC reoccurs by normal printing.
  3. Replace the engine board.