Before replacing the original feed unit, reset the PM counter.

  1. Turn the power ON and enter the SP mode.
  2. Execute the following SPs to reset the PM counter.
    - SP7-804-008 (Reset PM Counter: ADF Pickup)
    - SP7-804-009 (Reset PM Counter: ADF Feed)

  3. Turn the power OFF.

 

  1. Open the SPDF top cover.
  2. Slide the shaft [A] of the original feed unit toward the rear and remove it.