SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC816 | - | Energy save I/O subsystem error |
SC816-01 | D | Subsystem error |
SC816-02 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-03 | D | Transition to STR was denied. |
SC816-04 | D | Interrupt in kernel communication driver |
SC816-05 | D | Preparation for transition to STR failed. |
SC816-07 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-08 | D | Sysarch (LPUX_ENGINE_TIMERCTRL) error |
SC816-09 | D | Sysarch (LPUX_RETURN_FACTOR_STR) error |
SC816-10 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-11 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-12 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-13 | D | open() error |
SC816-14 | D | Memory address error |
SC816-15 | D | open() error |
SC816-16 | D | open() error |
SC816-17 | D | open() error |
SC816-18 | D | open() error |
SC816-19 | D | Double open() error |
SC816-20 | D | open() error |
SC816-22 | D | Parameter error |
SC816-23 | D | read() error |
SC816-24 | D | read() error |
SC816-25 | D | write() error |
SC816-26 | D | write() communication retry error |
SC816-27 | D | write() communication retry error |
SC816-28 | D | write() communication retry error |
SC816-29 | D | read() communication retry error |
SC816-30 | D | read() communication retry error |
SC816-35 | D | read() error |
SC816-36 to -98 | D | Subsystem error |
Energy save I/O subsystem detected some abnormality. | ||
| ||
Power cycle the machine to see if the error reoccurs. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power off/on after each step.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC819-00
| D | Fatal kernel error [XXXX]: Detailed error code |
[0x5032]
| HAIC-P2 error | |
HAIC-P2 decompression error (An error occurred in the ASIC compression/decompression module.) | ||
| ||
[0x5245] | Link up error | |
0x53554D45 -> "Link up error" | ||
| ||
[0c5355] | L2 status timeout | |
0x5350454E44 -> "L2 status time out" | ||
| ||
[0x6261]
| HDD defective | |
6261 6420 6469 7200 00 -> "bad dir" | ||
Power cycle the machine. | ||
[0x696e]
| gwinit process ending | |
If an unexpected error occurs at SCS processing end, gwint processing also halts (this result is judged a kernel stop error, by gwinit specification) “0x69742064” -> “init died” | ||
Power cycle the machine. | ||
Console string
| Other error (characters on operation panel) | |
Error in the OS | ||
Power cycle the machine. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC840-00 | D | EEPROM access error |
| ||
EEPROM is defective or has reached its end of life. | ||
- |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC841-00 | D | EEPROM read data error |
Mirrored data of the EEPROM is different from the original data in EEPROM. | ||
Data in the EEPROM is overwritten for some reason. | ||
- |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-00
| C | Nand-Flash updating verification error |
SCS write error (verify error) occurred at the Nand-Flash module when remote ROM or main ROM was updated. | ||
Nand-Flash defective | ||
Power cycle the machine. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-01 | C | Insufficient Nand-Flash blocks (threshold exceeded) |
At startup, or when machine returned from energy saver mode, the Nand-Flash status was read and judged that the number of unusable blocks had exceeded the threshold, and then SCS generated the SC code. | ||
Number of unusable blocks exceeded the threshold for Nand-Flash | ||
Replace the controller board (Printer: Controller board, MF: SCB). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-02 | C | The number of Nand-Flash block deletions exceeded |
At startup, or when the machined returned from energy saver mode, the Nand-Flash was read and judged that the number of deleted blocks had exceeded the threshold, and then SCS generated this SC code. | ||
Number of blocks deleted exceeded threshold for Nand-Flash | ||
Replace the controller board (Printer: Controller board, MF: SCB). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC843-02 | B | eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) |
At startup, or when the machined returned from energy saver mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold. | ||
Number of blocks rewrote exceeded threshold for eMMC | ||
Replace the Smart Operation Panel. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC845-01 | D | Hardware error detected when the automatic firmware update: Engine board |
SC845-02 | D | Hardware error detected when the automatic firmware update: Controller board |
SC845-03 | D | Hardware error detected when the automatic firmware update: Operation panel (normal) |
SC845-04 | D | Hardware error detected when the automatic firmware update: Operation panel (Smart Operation Panel) |
SC845-05 | D | Hardware error detected when the automatic firmware update: FCU |
When updating the firmware automatically (ARFU), the firmware cannot be read or written normally, and the firmware update cannot be completed even by 3 retries. | ||
Hardware abnormality of the target board | ||
Replacing the target board. For SC852-02, HDD may cause the problem. Replace the HDD if the SC cannot be recovered by replacing the controller board. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC855-01 | B | Wireless LAN board error (driver attachment failure) |
Wireless LAN board error (wireless LAN card: 802.11 is covered) | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC857-00 | B | USB I/F Error |
The USB interface is unusable because of a driver error. | ||
USB driver error (There are three causes of USB error: RX error/CRC error/STALL. SC is issued only in the case of STALL.) | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC860-00 | B | HDD startup error at power on (HDD error) |
| ||
| ||
Format the HDD with SP5-832-001. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC860-01 | D | HDD file system error at power on (HDD error) |
Even one partition mount of HDD failed | ||
| ||
SC860-02 | D | HDD label error (HDD error) |
HDD partition information is abnormal | ||
| ||
SC860-03 | D | HDD encryption key error (HDD error) |
HDD encryption key could not be read with HDD encryption | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-01 | D | HDD data read failure |
The data written to the HDD cannot be read normally. | ||
Bad sectors were generated during operation. (An error occurred in an area that does not belong to a partition, such as a disk label area.) | ||
Guide for when to replace the HDD
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-01 | D | HDD data read failure (An error occurred in an area that does not belong to a partition, such as a disk label area.) |
SC863-02 | D | HDD data read failure (An error occurred in partition "a".) |
SC863-03 | D | HDD data read failure (An error occurred in partition "b".) |
SC863-04 | D | HDD data read failure (An error occurred in partition "c".) |
SC863-05 | D | HDD data read failure (An error occurred in partition "d".) |
SC863-06 | D | HDD data read failure (An error occurred in partition "e".) |
SC863-07 | D | HDD data read failure (An error occurred in partition "f".) |
SC863-08 | D | HDD data read failure (An error occurred in partition "g".) |
SC863-09 | D | HDD data read failure (An error occurred in partition "h".) |
SC863-10 | D | HDD data read failure (An error occurred in partition "i".) |
SC863-11 | D | HDD data read failure (An error occurred in partition "j".) |
SC863-12 | D | HDD data read failure (An error occurred in partition "k".) |
SC863-13 | D | HDD data read failure (An error occurred in partition "l".) |
SC863-14 | D | HDD data read failure (An error occurred in partition "m".) |
SC863-15 | D | HDD data read failure (An error occurred in partition "n".) |
SC863-16 | D | HDD data read failure (An error occurred in partition "o".) |
SC863-17 | D | HDD data read failure (An error occurred in partition "p".) |
SC863-18 | D | HDD data read failure (An error occurred in partition "q".) |
SC863-19 | D | HDD data read failure (An error occurred in partition "r".) |
SC863-20 | D | HDD data read failure (An error occurred in partition "s".) |
SC863-21 | D | HDD data read failure (An error occurred in partition "t".) |
SC863-22 | D | HDD data read failure (An error occurred in partition "u".) |
SC863-23 | D | HDD data read failure (An error occurred in partition "v".) |
The data written to the HDD cannot be read normally. | ||
Bad sectors were generated during operation. | ||
Guide for when to replace the HDD
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-01 | D | HDD data CRC error (An error occurred in an area that does not belong to a partition, such as a disk label area.) |
SC864-02 | D | HDD data CRC error (An error occurred in partition "a".) |
SC864-03 | D | HDD data CRC error (An error occurred in partition "b".) |
SC864-04 | D | HDD data CRC error (An error occurred in partition "c".) |
SC864-05 | D | HDD data CRC error (An error occurred in partition "d".) |
SC864-06 | D | HDD data CRC error (An error occurred in partition "e".) |
SC864-07 | D | HDD data CRC error (An error occurred in partition "f".) |
SC864-08 | D | HDD data CRC error (An error occurred in partition "g".) |
SC864-09 | D | HDD data CRC error (An error occurred in partition "h".) |
SC864-10 | D | HDD data CRC error (An error occurred in partition "i".) |
SC864-11 | D | HDD data CRC error (An error occurred in partition "j".) |
SC864-12 | D | HDD data CRC error (An error occurred in partition "k".) |
SC864-13 | D | HDD data CRC error (An error occurred in partition "l".) |
SC864-14 | D | HDD data CRC error (An error occurred in partition "m".) |
SC864-15 | D | HDD data CRC error (An error occurred in partition "n".) |
SC864-16 | D | HDD data CRC error (An error occurred in partition "o".) |
SC864-17 | D | HDD data CRC error (An error occurred in partition "p".) |
SC864-18 | D | HDD data CRC error (An error occurred in partition "q".) |
SC864-19 | D | HDD data CRC error (An error occurred in partition "r".) |
SC864-20 | D | HDD data CRC error (An error occurred in partition "s".) |
SC864-21 | D | HDD data CRC error (An error occurred in partition "t".) |
SC864-22 | D | HDD data CRC error (An error occurred in partition "u".) |
SC864-23 | D | HDD data CRC error (An error occurred in partition "v".) |
During HDD operation, the HDD returned a CRC error. | ||
Bad sectors were generated during operation. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-01 | D | HDD access error (An error occurred in an area that does not belong to a partition, such as a disk label area.) |
SC865-02 | D | HDD access error (An error occurred in partition "a".) |
SC865-03 | D | HDD access error (An error occurred in partition "b".) |
SC865-04 | D | HDD access error (An error occurred in partition "c".) |
SC865-05 | D | HDD access error (An error occurred in partition "d".) |
SC865-06 | D | HDD access error (An error occurred in partition "e".) |
SC865-07 | D | HDD access error (An error occurred in partition "f".) |
SC865-08 | D | HDD access error(An error occurred in partition "g".) |
SC865-09 | D | HDD access error (An error occurred in partition "h".) |
SC865-10 | D | HDD access error (An error occurred in partition "i".) |
SC865-11 | D | HDD access error (An error occurred in partition "j".) |
SC865-12 | D | HDD access error (An error occurred in partition "k".) |
SC865-13 | D | HDD access error (An error occurred in partition "l".) |
SC865-14 | D | HDD access error (An error occurred in partition "m".) |
SC865-15 | D | HDD access error (An error occurred in partition "n".) |
SC865-16 | D | HDD access error (An error occurred in partition "o".) |
SC865-17 | D | HDD access error (An error occurred in partition "p".) |
SC865-18 | D | HDD access error (An error occurred in partition "q".) |
SC865-19 | D | HDD access error (An error occurred in partition "r".) |
SC865-20 | D | HDD access error (An error occurred in partition "s".) |
SC865-21 | D | HDD access error (An error occurred in partition "t".) |
SC865-22 | D | HDD access error (An error occurred in partition "u".) |
SC865-23 | D | HDD access error (An error occurred in partition "v".) |
During HDD operation, the HDD returned an error. | ||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). | ||
Replace the HDD. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-50 | D | HDD time-out error (An error occurred in an unknown area.) |
SC865-51 | D | HDD time-out error (An error occurred in an area that does not belong to a partition.) |
SC865-52 | D | HDD time-out error (An error occurred in partition "a".) |
SC865-53 | D | HDD time-out error (An error occurred in partition "b".) |
SC865-54 | D | HDD time-out error (An error occurred in partition "c".) |
SC865-55 | D | HDD time-out error (An error occurred in partition "d".) |
SC865-56 | D | HDD time-out error (An error occurred in partition "e".) |
SC865-57 | D | HDD time-out error (An error occurred in partition "f".) |
SC865-58 | D | HDD time-out error(An error occurred in partition "g".) |
SC865-59 | D | HDD time-out error (An error occurred in partition "h".) |
SC865-60 | D | HDD time-out error (An error occurred in partition "i".) |
SC865-61 | D | HDD time-out error (An error occurred in partition "j".) |
SC865-62 | D | HDD time-out error (An error occurred in partition "k".) |
SC865-63 | D | HDD time-out error (An error occurred in partition "l".) |
SC865-64 | D | HDD time-out error (An error occurred in partition "m".) |
SC865-65 | D | HDD time-out error (An error occurred in partition "n".) |
SC865-66 | D | HDD time-out error (An error occurred in partition "o".) |
SC865-67 | D | HDD time-out error (An error occurred in partition "p".) |
SC865-68 | D | HDD time-out error (An error occurred in partition "q".) |
SC865-69 | D | HDD time-out error (An error occurred in partition "r".) |
SC865-70 | D | HDD time-out error (An error occurred in partition "s".) |
SC865-72 | D | HDD time-out error (An error occurred in partition "t".) |
SC865-72 | D | HDD time-out error (An error occurred in partition "u".) |
SC865-73 | D | HDD time-out error (An error occurred in partition "v".) |
The machine does not detect a reply from the HDD during the HDD operation. | ||
The HDD does not respond to the read/ write command from the machine. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC866-00 | B | SD card authentication error |
When a correct license for digital authentication is not found in an SD card application. | ||
The SD card contains the wrong program data. | ||
Store the correct program data on the SD card. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC867-00 | B | SD card removal detection |
When an application SD card is removed from the slot (/mnt/sd0) while the application is being activated. | ||
SC867-01 | B | SD card removal detection |
When an application SD card is removed from the slot (/mnt/sd1) while the application is being activated. | ||
SC867-02 | B | SD card removal detection |
When an application SD card is removed from the slot (/mnt/sd2) while the application is being activated. | ||
An application SD card has been removed from the slot (from the mount point /mnt/sd*). | ||
Power cycle the machine. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC868-00 | D
| SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd0) | ||
SC868-01 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) | ||
SC868-02 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd2) | ||
| ||
SD card that starts an application:
SD card for users:
|
* Do not format the SD card supplied with the main machine or sold as an option. You may only format SD cards used for firmware update by the Customer Engineer.
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC870-00 | B | Address book data error (Anytime: Address book error.) |
SC870-01 | B | Address book data error (On startup: Media required for storing the address book is missing.) |
SC870-02 | B | Address book data error (On startup: encryption is configured but the module required for encryption (DESS) is missing.) |
SC870-03 | B | Address book data error (Initialization: Failed to generate a file to store internal address book.) |
SC870-04 | B | Address book data error (Initialization: Failed to generate a file to store delivery sender.) |
SC870-05 | B | Address book data error (Initialization: Failed to generate a file to store delivery destination.) |
SC870-06 | B | Address book data error (Initialization: Failed to generate a file to store information required for LDAP search.) |
SC870-07 | B | Address book data error (Initialization: Failed to initialize entries required for machine operation.) |
SC870-08 | B | Address book data error (Machine configuration: HDD is present but the space for storing the address book is unusable.) |
SC870-10 | B | Address book data error (Machine configuration: Cannot make a directory for storing the address book in the SD/USB FlashROM.) |
SC870-11 | B | Address book data error (On startup: Inconsistency in the address book entry number.) |
SC870-20 | B | Address book data error (File I/O: Failed to initialize file.) |
SC870-21 | B | Address book data error (File I/O: Failed to generate the file.) |
SC870-22 | B | Address book data error (File I/O: Failed to open the file.) |
SC870-23 | B | Address book data error (File I/O: Failed to write to file.) |
SC870-24 | B | Address book data error (File I/O: Failed to read the file.) |
SC870-25 | B | Address book data error (File I/O: Failed to check the file size.) |
SC870-26 | B | Address book data error (File I/O: Failed to delete data.) |
SC870-27 | B | Address book data error (File I/O: Failed to add data.) |
SC870-30 | B | Address book data error (Search: Failed to obtain data from the cache when searching in the machine address book. delivery destination/sender.) |
SC870-31 | B | Address book data error (Search: Failed to obtain data from cache during LDAP search.) |
SC870-32 | B | Address book data error (Search: Failed to obtain data from cache while searching the WS-scanner address book.) |
SC870-41 | B | Address book data error (Cache: failed to obtain data from the cache.) |
SC870-50 | B | Address book data error (On startup: Detected abnormality of the address book encryption status.) |
SC870-51 | B | Address book data error (Encryption settings: Failed to create the directory required for conversion between plaintext and encrypted text.) |
SC870-52 | B | Address book data error (Encryption settings: Failed to convert from plaintext to encrypted text.) |
SC870-53 | B | Address book data error (Encryption settings: Failed to convert from encrypted text to plain text.) |
SC870-54 | B | Address book data error (Encryption settings: Detected data inconsistency when reading the encrypted address book.) |
SC870-55 | B | Address book data error (Encryption settings: Failed to delete the file when changing encryption setting.) |
SC870-56 | B | Address book data error (Encryption settings: Failed to erase the file that records the encryption key during an attempt to change the encryption setting.) |
SC870-57 | B | Address book data error (Encryption settings: Failed to move a file during an attempt to change the encryption setting.) |
SC870-58 | B | Address book data error (Encryption settings: Failed to delete a directory during an attempt to change the encryption setting.) |
SC870-59 | B | Address book data error (Encryption settings: Detected a resource shortage during an attempt to change the encryption setting.) |
SC870-60 | B | Address Book data error (Unable to obtain the on/off setting for administrator authentication.) |
When an error related to the Address Book is detected during startup or operation. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC871-01 | D | FCU error |
An error occurred when FCS detects FCU defective. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC874-05 | D | Delete all error (Delete data area) : Read error |
SC874-06 | D | Delete all error (Delete data area) : Write error |
SC874-09 | D | Delete all error (Delete data area) : No response from HDD |
SC874-10 | D | Delete all error (Delete data area) : Error in Kernel |
SC874-12 | D | Delete all error (Delete data area) : No designated partition |
SC874-13 | D | Delete all error (Delete data area) : No device file |
SC874-14 | D | Delete all error (Delete data area) : Start option error |
SC874-15 | D | Delete all error (Delete data area) : No designated sector number |
SC874-16 | D | Delete all error (Delete data area) : failure in performing hdd erase |
SC874-41 | D | Delete all error (Delete data area) : Other fatal errors |
SC874-42 | D | Delete all error (Delete data area) : End by cancellation |
SC874-61 | D | Delete all error (Delete data area) : Library error |
SC874-62 | D | Delete all error (Delete data area) : Library error |
SC874-63 | D | Delete all error (Delete data area) : Library error |
SC874-64 | D | Delete all error (Delete data area) : Library error |
SC874-65 | D | Delete all error (Delete data area) : Library error |
SC874-66 | D | Delete all error (Delete data area) : Unavailable |
SC874-67 | D | Delete all error (Delete data area) : Erasing not finished |
SC874-68 | D | Delete all error (Delete data area) : HDD format failure (Normal) |
SC874-69 | D | Delete all error (Delete data area) : HDD format failure (Abnormal) |
SC874-70 | D | Delete all error (Delete data area) : Unauthorized library |
SC874-99 | D | Delete all error (Delete data area) : other errors |
An error occurred while data was being erased on HDD or NVRAM | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC875-01 | D | Delete all error (HDD erasure) (hddchack –i error) |
SC875-02 | D | Delete all error (HDD erasure) (Data deletion failure) |
An error was detected before HDD/data erasure starts. (Failed to erase data/failed to logically format HDD) | ||
| ||
Power cycle the machine. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC877-00 | B | Data Overwrite Security card error |
The "Auto Erase Memory" function of the Data Overwrite Security is enabled but it cannot be executed. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-00 | D | TPM electronic authentication error |
The machine failed TPM electronic authentication. System hash registered in the TPM did not match the data on the USB flash. | ||
| ||
Replace the controller board (Printer: Controller board, MF: SCB). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-01 | D | USB Flash error |
USB Flash file system error | ||
USB Flash file system has been destroyed. | ||
Replace the controller board (Printer: Controller board, MF: SCB). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-02 | D | TPM error |
An error occurred in the TPM or TPM driver. | ||
TPM is defective | ||
Replace the controller board (Printer: Controller board, MF: SCB). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-03 | D | TCSD error |
An error occurred in TPM software stack. | ||
| ||
Replace the controller board (Printer: Controller board, MF: SCB). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-20 | D | Random Number Generator Error |
An error occurred when doing self-check against seed for random number generated. | ||
TPM is defective | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC899-00 | D | Software performance error (signal reception end) |
- | ||
Occurs when an internal program behaves abnormally. | ||
In the case of a hardware defect
In the case of a software error
|