SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC816

-

Energy save I/O subsystem error

SC816-01

D

Subsystem error

SC816-02

D

Sysarch (LPUX_GET_PORT_INFO) error

SC816-03

D

Transition to STR was denied.

SC816-04

D

Interrupt in kernel communication driver

SC816-05

D

Preparation for transition to STR failed.

SC816-07

D

Sysarch (LPUX_GET_PORT_INFO) error

SC816-08

D

Sysarch (LPUX_ENGINE_TIMERCTRL) error

SC816-09

D

Sysarch (LPUX_RETURN_FACTOR_STR) error

SC816-10

D

Sysarch (LPUX_GET_PORT_INFO) error

SC816-11DSysarch (LPUX_GET_PORT_INFO) error
SC816-12DSysarch (LPUX_GET_PORT_INFO) error

SC816-13

D

open() error

SC816-14

D

Memory address error

SC816-15

D

open() error

SC816-16Dopen() error
SC816-17Dopen() error
SC816-18Dopen() error

SC816-19

D

Double open() error

SC816-20

D

open() error

SC816-22

D

Parameter error

SC816-23

D

read() error

SC816-24Dread() error

SC816-25

D

write() error

SC816-26

D

write() communication retry error

SC816-27Dwrite() communication retry error
SC816-28Dwrite() communication retry error

SC816-29

D

read() communication retry error

SC816-30Dread() communication retry error

SC816-35

D

read() error

SC816-36

to -98

D

Subsystem error

  

Energy save I/O subsystem detected some abnormality.

  • Energy save I/O subsystem defective
  • Energy save I/O subsystem detected a controller board error (non-response).
  • An error was detected during preparation for the transition to STR.

Power cycle the machine to see if the error reoccurs. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power off/on after each step.

  1. Update the "System/Copy" firmware and the other system firmware to the latest version.

  2. Disable the STR shift function with SP5-191-001 (Power Str Set).

  3. Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC819-00

 

 


 

 

 

D

Fatal kernel error

[XXXX]: Detailed error code

[0x5032]

 

HAIC-P2 error

HAIC-P2 decompression error (An error occurred in the ASIC compression/decompression module.)

  1. Power cycle the machine.
  2. Replace the HDD.
  3. Replace the controller board (Printer: Controller board, MF: SCB).

[0x5245]

Link up error
0x53554D45  -> "Link up error"
  1. Power cycle the machine.
  2. Replace the controller board (Printer: Controller board, MF: SCB).
  3. Replace the engine board (Printer: BCU, MF: SCB).
[0c5355]L2 status timeout
0x5350454E44  -> "L2 status time out"
  1. Power cycle the machine.
  2. Replace the controller board (Printer: Controller board, MF: SCB).
  3. Replace the engine board (Printer: BCU, MF: SCB).

[0x6261]

 

HDD defective

6261 6420 6469 7200 00 -> "bad dir"

Power cycle the machine.

[0x696e]

 

gwinit process ending

If an unexpected error occurs at SCS processing end, gwint processing also halts (this result is judged a kernel stop error, by gwinit specification)

“0x69742064” -> “init died”

Power cycle the machine.

Console string

 

 

 

Other error (characters on operation panel)

Error in the OS

Power cycle the machine.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC840-00

D

EEPROM access error

  • During the I/O processing, a reading error occurred. The 3rd reading failure causes this SC code.
  • During the I/O processing, a writing error occurred.

EEPROM is defective or has reached its end of life.

-

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC841-00

D

EEPROM read data error

Mirrored data of the EEPROM is different from the original data in EEPROM.

Data in the EEPROM is overwritten for some reason.

-

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC842-00

 

 

 

C

Nand-Flash updating verification error

SCS write error (verify error) occurred at the Nand-Flash module when remote ROM or main ROM was updated.

Nand-Flash defective

Power cycle the machine.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC842-01

C

Insufficient Nand-Flash blocks (threshold exceeded)

At startup, or when machine returned from energy saver mode, the Nand-Flash status was read and judged that the number of unusable blocks had exceeded the threshold, and then SCS generated the SC code.

Number of unusable blocks exceeded the threshold for Nand-Flash

Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC842-02

C

The number of Nand-Flash block deletions exceeded

At startup, or when the machined returned from energy saver mode, the Nand-Flash was read and judged that the number of deleted blocks had exceeded the threshold, and then SCS generated this SC code.

Number of blocks deleted exceeded threshold for Nand-Flash

Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC843-02

B

eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) 

At startup, or when the machined returned from energy saver mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.

Number of blocks rewrote exceeded threshold for eMMC

Replace the Smart Operation Panel.

 

 

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC845-01

D

Hardware error detected when the automatic firmware update: Engine board

SC845-02DHardware error detected when the automatic firmware update: Controller board
SC845-03DHardware error detected when the automatic firmware update: Operation panel (normal)
SC845-04DHardware error detected when the automatic firmware update: Operation panel (Smart Operation Panel)
SC845-05DHardware error detected when the automatic firmware update: FCU
  When updating the firmware automatically (ARFU), the firmware cannot be read or written normally, and the firmware update cannot be completed even by 3 retries.

Hardware abnormality of the target board

Replacing the target board.

For SC852-02, HDD may cause the problem. Replace the HDD if the SC cannot be recovered by replacing the controller board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC855-01

B

Wireless LAN board error (driver attachment failure)

Wireless LAN board error (wireless LAN card: 802.11 is covered)

  • Defective wireless LAN board
  • Loose connection
  1. Power cycle the machine.
  2. Replace wireless LAN board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC857-00

B

USB I/F Error

The USB interface is unusable because of a driver error.

USB driver error (There are three causes of USB error: RX error/CRC error/STALL. SC is issued only in the case of STALL.)
  1. Check the USB connection.
  2. Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC860-00




B




HDD startup error at power on (HDD error)

  • The HDD is connected but the driver detected the following errors.
    • SS_NO.T_READY: (-2): HDD does not become READY
    • SS_BAD_LABEL: (-4): Partition type incorrect
    • SS_READ_ERROR: (-5): Error occurred while reading or checking the label
    • SS_WRITE_ERROR: (-6): Error occurred while writing or checking the label
    • SS_FS_ERROR: (-7): Failed to repair the filesystem
    • SS_MOUNT_ERROR: (-8): Failed to mount the filesystem
    • SS_COMMAND_ERROR: (-9): Drive not responding to the command
    • SS_KERNEL_ERROR: (-10): Internal kernel error
    • SS_SIZE_ERROR: (-11): Drive size too small
    • SS_NO._PARTITION:(-12): The specified partition does not exist
    • SS_NO._FILE: (-13): Device file does not exist
  • Attempted to acquire HDD status through the driver but there has been no response for 300 seconds or more.
  • Unformatted HDD
  • Label data corrupted
  • HDD defective

Format the HDD with SP5-832-001.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC860-01




D

HDD file system error at power on (HDD error)

Even one partition mount of HDD failed 

  • Power off during file writing to HDD
  • Shutting down while writing the file to HDD 
SC860-02DHDD label error (HDD error)
HDD partition information is abnormal  
  • Power off during HDD initialization 
  • HDD defective 
SC860-03DHDD encryption key error (HDD error)
HDD encryption key could not be read with HDD encryption
 Simultaneous breakage of the controller's ROM (NAND) and NVRAM
  
  1. Power cycle the machine.
  2. Format the HDD with SP5-832-001.
  3. Replace the HDD.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC863-01

D

HDD data read failure

The data written to the HDD cannot be read normally.

Bad sectors were generated during operation.

(An error occurred in an area that does not belong to a partition, such as a disk label area.)

Guide for when to replace the HDD

  1. When SC863 has occurred ten times or more
    • The interval is short.
    • Repeatedly occurs in the same situation (At power-on, etc.).
    • Startup takes a long time when the main power is turned on.
  2. It takes a long time after main power on for the operation panel to become ready.
    HDD access may be consuming time. Normal HDD access time after main power on is about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20 to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD, HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data and check them.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC863-01

D

HDD data read failure (An error occurred in an area that does not belong to a partition, such as a disk label area.)

SC863-02DHDD data read failure (An error occurred in partition "a".)
SC863-03DHDD data read failure (An error occurred in partition "b".)
SC863-04DHDD data read failure (An error occurred in partition "c".)
SC863-05DHDD data read failure (An error occurred in partition "d".)
SC863-06DHDD data read failure (An error occurred in partition "e".)
SC863-07DHDD data read failure (An error occurred in partition "f".)
SC863-08DHDD data read failure (An error occurred in partition "g".)
SC863-09DHDD data read failure (An error occurred in partition "h".)
SC863-10DHDD data read failure (An error occurred in partition "i".)
SC863-11DHDD data read failure (An error occurred in partition "j".)
SC863-12DHDD data read failure (An error occurred in partition "k".)

SC863-13

DHDD data read failure (An error occurred in partition "l".)
SC863-14DHDD data read failure (An error occurred in partition "m".)
SC863-15DHDD data read failure (An error occurred in partition "n".)
SC863-16DHDD data read failure (An error occurred in partition "o".)
SC863-17DHDD data read failure (An error occurred in partition "p".)
SC863-18DHDD data read failure (An error occurred in partition "q".)
SC863-19DHDD data read failure (An error occurred in partition "r".)
SC863-20DHDD data read failure (An error occurred in partition "s".)
SC863-21DHDD data read failure (An error occurred in partition "t".)
SC863-22DHDD data read failure (An error occurred in partition "u".)
SC863-23DHDD data read failure (An error occurred in partition "v".)
  

The data written to the HDD cannot be read normally.

Bad sectors were generated during operation.

Guide for when to replace the HDD

  1. When SC863 has occurred ten times or more
    • The interval is short.
    • Repeatedly occurs in the same situation (At power-on, etc.).
    • Startup takes a long time when the main power is turned on.
  2. It takes a long time after main power on for the operation panel to become ready.
    HDD access may be consuming time. Normal HDD access time after main power on is about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20 to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD, HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data and check them.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC864-01

D

HDD data CRC error (An error occurred in an area that does not belong to a partition, such as a disk label area.)

SC864-02DHDD data CRC error (An error occurred in partition "a".)
SC864-03DHDD data CRC error (An error occurred in partition "b".)
SC864-04DHDD data CRC error (An error occurred in partition "c".)
SC864-05DHDD data CRC error (An error occurred in partition "d".)
SC864-06DHDD data CRC error (An error occurred in partition "e".)
SC864-07DHDD data CRC error (An error occurred in partition "f".)
SC864-08DHDD data CRC error (An error occurred in partition "g".)
SC864-09DHDD data CRC error (An error occurred in partition "h".)
SC864-10DHDD data CRC error (An error occurred in partition "i".)
SC864-11DHDD data CRC error (An error occurred in partition "j".)
SC864-12DHDD data CRC error (An error occurred in partition "k".)

SC864-13

DHDD data CRC error (An error occurred in partition "l".)
SC864-14DHDD data CRC error (An error occurred in partition "m".)
SC864-15DHDD data CRC error (An error occurred in partition "n".)
SC864-16DHDD data CRC error (An error occurred in partition "o".)
SC864-17DHDD data CRC error (An error occurred in partition "p".)
SC864-18DHDD data CRC error (An error occurred in partition "q".)
SC864-19DHDD data CRC error (An error occurred in partition "r".)
SC864-20DHDD data CRC error (An error occurred in partition "s".)
SC864-21DHDD data CRC error (An error occurred in partition "t".)
SC864-22DHDD data CRC error (An error occurred in partition "u".)
SC864-23DHDD data CRC error (An error occurred in partition "v".)
  

During HDD operation, the HDD returned a CRC error.

Bad sectors were generated during operation.

  1. Format the HDD.
  2. Replace the HDD.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC865-01

D

HDD access error (An error occurred in an area that does not belong to a partition, such as a disk label area.)

SC865-02DHDD access error (An error occurred in partition "a".)
SC865-03DHDD access error (An error occurred in partition "b".)
SC865-04DHDD access error (An error occurred in partition "c".)
SC865-05DHDD access error (An error occurred in partition "d".)
SC865-06DHDD access error (An error occurred in partition "e".)
SC865-07DHDD access error (An error occurred in partition "f".)
SC865-08DHDD access error(An error occurred in partition "g".)
SC865-09DHDD access error (An error occurred in partition "h".)
SC865-10DHDD access error (An error occurred in partition "i".)
SC865-11DHDD access error (An error occurred in partition "j".)
SC865-12DHDD access error (An error occurred in partition "k".)

SC865-13

DHDD access error (An error occurred in partition "l".)
SC865-14DHDD access error (An error occurred in partition "m".)
SC865-15DHDD access error (An error occurred in partition "n".)
SC865-16DHDD access error (An error occurred in partition "o".)
SC865-17DHDD access error (An error occurred in partition "p".)
SC865-18DHDD access error (An error occurred in partition "q".)
SC865-19DHDD access error (An error occurred in partition "r".)
SC865-20DHDD access error (An error occurred in partition "s".)
SC865-21DHDD access error (An error occurred in partition "t".)
SC865-22DHDD access error (An error occurred in partition "u".)
SC865-23DHDD access error (An error occurred in partition "v".)
  

During HDD operation, the HDD returned an error.

The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error).

Replace the HDD.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC865-50

D

HDD time-out error (An error occurred in an unknown area.)

SC865-51DHDD time-out error (An error occurred in an area that does not belong to a partition.)
SC865-52DHDD time-out error (An error occurred in partition "a".)
SC865-53DHDD time-out error (An error occurred in partition "b".)
SC865-54DHDD time-out error (An error occurred in partition "c".)
SC865-55DHDD time-out error (An error occurred in partition "d".)
SC865-56DHDD time-out error (An error occurred in partition "e".)
SC865-57DHDD time-out error (An error occurred in partition "f".)
SC865-58DHDD time-out error(An error occurred in partition "g".)
SC865-59DHDD time-out error (An error occurred in partition "h".)
SC865-60DHDD time-out error (An error occurred in partition "i".)
SC865-61DHDD time-out error (An error occurred in partition "j".)
SC865-62DHDD time-out error (An error occurred in partition "k".)

SC865-63

DHDD time-out error (An error occurred in partition "l".)
SC865-64DHDD time-out error (An error occurred in partition "m".)
SC865-65DHDD time-out error (An error occurred in partition "n".)
SC865-66DHDD time-out error (An error occurred in partition "o".)
SC865-67DHDD time-out error (An error occurred in partition "p".)
SC865-68DHDD time-out error (An error occurred in partition "q".)
SC865-69DHDD time-out error (An error occurred in partition "r".)
SC865-70DHDD time-out error (An error occurred in partition "s".)
SC865-72DHDD time-out error (An error occurred in partition "t".)
SC865-72DHDD time-out error (An error occurred in partition "u".)
SC865-73DHDD time-out error (An error occurred in partition "v".)
  

The machine does not detect a reply from the HDD during the HDD operation.

The HDD does not respond to the read/ write command from the machine.

  1. Check the harness connections between the controller board and HDD.
  2. Replace the HDD.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC866-00

B

SD card authentication error

When a correct license for digital authentication is not found in an SD card application.

The SD card contains the wrong program data.

Store the correct program data on the SD card.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC867-00

B

SD card removal detection

When an application SD card is removed from the slot (/mnt/sd0) while the application is being activated.
SC867-01BSD card removal detection
When an application SD card is removed from the slot (/mnt/sd1) while the application is being activated.

SC867-02

B

SD card removal detection

When an application SD card is removed from the slot (/mnt/sd2) while the application is being activated.
  

An application SD card has been removed from the slot (from the mount point /mnt/sd*).

Power cycle the machine.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC868-00

D

 

SD card access error

The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd0)

SC868-01DSD card access error
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1)
SC868-02DSD card access error
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd2)
 

  • SD card defective
  • SD controller defective

SD card that starts an application:

  • Power cycle the machine and check the SD card insertion status.
  • If no problem is found, insert the SD card and turn the main power on.
  • If an error occurs, replace the SD card.

SD card for users:

  • In case of a file system error, reformat the SD card (using the "SD Formatter" made by Panasonic).*
  • In case of a device access error, turn the power off and check the SD card insertion status.
    • If no problem is found, insert the SD card and turn the power on.
    • If an error occurs, use another SD card.
    • If the error persists even after replacing the SD card, replace the controller board.

* Do not format the SD card supplied with the main machine or sold as an option. You may only format SD cards used for firmware update by the Customer Engineer.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC870-00

B

Address book data error (Anytime: Address book error.)

SC870-01

B

Address book data error (On startup: Media required for storing the address book is missing.)

SC870-02

B

Address book data error (On startup: encryption is configured but the module required for encryption (DESS) is missing.)

SC870-03

B

Address book data error (Initialization: Failed to generate a file to store internal address book.)

SC870-04

B

Address book data error (Initialization: Failed to generate a file to store delivery sender.)

SC870-05

B

Address book data error (Initialization: Failed to generate a file to store delivery destination.)

SC870-06

B

Address book data error (Initialization: Failed to generate a file to store information required for LDAP search.)

SC870-07

B

Address book data error (Initialization: Failed to initialize entries required for machine operation.)

SC870-08

B

Address book data error (Machine configuration: HDD is present but the space for storing the address book is unusable.)

SC870-10

B

Address book data error (Machine configuration: Cannot make a directory for storing the address book in the SD/USB FlashROM.)

SC870-11

B

Address book data error (On startup: Inconsistency in the address book entry number.)

SC870-20

B

Address book data error (File I/O: Failed to initialize file.)

SC870-21

B

Address book data error (File I/O: Failed to generate the file.)

SC870-22

B

Address book data error (File I/O: Failed to open the file.)

SC870-23

B

Address book data error (File I/O: Failed to write to file.)

SC870-24

B

Address book data error (File I/O: Failed to read the file.)

SC870-25

B

Address book data error (File I/O: Failed to check the file size.)

SC870-26

B

Address book data error (File I/O: Failed to delete data.)

SC870-27

B

Address book data error (File I/O: Failed to add data.)

SC870-30

B

Address book data error (Search: Failed to obtain data from the cache when searching in the machine address book. delivery destination/sender.)

SC870-31

B

Address book data error (Search: Failed to obtain data from cache during LDAP search.)

SC870-32

B

Address book data error (Search: Failed to obtain data from cache while searching the WS-scanner address book.)

SC870-41

B

Address book data error (Cache: failed to obtain data from the cache.)

SC870-50

B

Address book data error (On startup: Detected abnormality of the address book encryption status.)

SC870-51

B

Address book data error (Encryption settings: Failed to create the directory required for conversion between plaintext and encrypted text.)

SC870-52

B

Address book data error (Encryption settings: Failed to convert from plaintext to encrypted text.)

SC870-53

B

Address book data error (Encryption settings: Failed to convert from encrypted text to plain text.)

SC870-54

B

Address book data error (Encryption settings: Detected data inconsistency when reading the encrypted address book.)

SC870-55

B

Address book data error (Encryption settings: Failed to delete the file when changing encryption setting.)

SC870-56

B

Address book data error (Encryption settings: Failed to erase the file that records the encryption key during an attempt to change the encryption setting.)

SC870-57

B

Address book data error (Encryption settings: Failed to move a file during an attempt to change the encryption setting.)

SC870-58

B

Address book data error (Encryption settings: Failed to delete a directory during an attempt to change the encryption setting.)

SC870-59

B

Address book data error (Encryption settings: Detected a resource shortage during an attempt to change the encryption setting.)

SC870-60BAddress Book data error (Unable to obtain the on/off setting for administrator authentication.)
  

When an error related to the Address Book is detected during startup or operation.

  • Software bug
  • Inconsistency of Address Book source location (machine/delivery server/LDAP server)
  • Inconsistency of Address Book encryption setting or encryption key (NVRAM or HDD was replaced individually without formatting the Address Book)
  • The address Book storage device (SD/HDD) was temporarily removed or hardware configuration does not match the application configuration.
  • Address Book data corruption was detected.
  1. Check the HDD connection.
  2. Initialize all UCS settings and address/authentication information (SP5-846-046).
  3. Initialize the address book partition (SP5-832-006).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC871-01

D

FCU error

An error occurred when FCS detects FCU defective.

  • Time-out error
  • Abnormal parameter
  1. Power cycle the machine.
  2. Update the firmware if the more recent firmware was released.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC874-05

D

Delete all error (Delete data area) : Read error

SC874-06DDelete all error (Delete data area) : Write error
SC874-09DDelete all error (Delete data area) : No response from HDD
SC874-10DDelete all error (Delete data area) : Error in Kernel
SC874-12DDelete all error (Delete data area) : No designated partition
SC874-13DDelete all error (Delete data area) : No device file
SC874-14DDelete all error (Delete data area) : Start option error
SC874-15DDelete all error (Delete data area) : No designated sector number
SC874-16DDelete all error (Delete data area) : failure in performing hdd erase
SC874-41DDelete all error (Delete data area) : Other fatal errors
SC874-42DDelete all error (Delete data area) : End by cancellation
SC874-61DDelete all error (Delete data area) : Library error
SC874-62DDelete all error (Delete data area) : Library error
SC874-63DDelete all error (Delete data area) : Library error
SC874-64DDelete all error (Delete data area) : Library error
SC874-65DDelete all error (Delete data area) : Library error
SC874-66DDelete all error (Delete data area) : Unavailable
SC874-67DDelete all error (Delete data area) : Erasing not finished
SC874-68DDelete all error (Delete data area) : HDD format failure (Normal)
SC874-69DDelete all error (Delete data area) : HDD format failure (Abnormal)
SC874-70DDelete all error (Delete data area) : Unauthorized library
SC874-99DDelete all error (Delete data area) : other errors
  

An error occurred while data was being erased on HDD or NVRAM

  • Error detected in HDD data delete the program
  • Error detected in NVRAM data delete the program
  • The "Delete All" option was not set
  1. Turn the main power switch off and back on, and then execute "Erase All Memory" under UP mode again. (However, if there is a defective sector or other problem with the hard disk, the error will persist even after trying the above.)
  2. If the "Delete All" option is not installed when this error occurs, install the option.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC875-01

D

Delete all error (HDD erasure) (hddchack –i error)

SC875-02DDelete all error (HDD erasure) (Data deletion failure)
  

An error was detected before HDD/data erasure starts. (Failed to erase data/failed to logically format HDD)

  • HDD logical formatting failed.
  • The modules failed to erase data.

Power cycle the machine.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC877-00

B

Data Overwrite Security card error

The "Auto Erase Memory" function of the Data Overwrite Security is enabled but it cannot be executed.

  • Data Overwrite Security option SD card is broken.
  • Data Overwrite Security option SD card has been removed.
  • If the SD card is broken, prepare a new Data Overwrite Security option SD card and replace the NVRAM.
  • If the SD card has been removed, turn the main power off and reinstall a working Data Overwrite Security option SD card.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC878-00

D

TPM electronic authentication error

The machine failed TPM electronic authentication.

System hash registered in the TPM did not match the data on the USB flash.

  • System module was updated in an unauthorized manner.
  • USB flash is not working correctly.

Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC878-01

D

USB Flash error

USB Flash file system error

USB Flash file system has been destroyed.

Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC878-02

D

TPM error

An error occurred in the TPM or TPM driver.

TPM is defective

Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC878-03

D

TCSD error

An error occurred in TPM software stack.

  • Unable to start TPM
  • Necessary files missing from the TPM.

Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC878-20

D

Random Number Generator Error
An error occurred when doing self-check against seed for random number generated.
TPM is defective
  • Power cycle the machine.
  • Replace the controller board (Printer: Controller board, MF: SCB).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC899-00

D

Software performance error (signal reception end)

 

-

Occurs when an internal program behaves abnormally.

In the case of a hardware defect

  • Replace the hardware.

In the case of a software error

  • Power cycle the machine.
  • Try updating the firmware.