SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC940-81 | D | Load SW overcurrent detection |
Current limiting to the load SW has been detected. | ||
Shortcircuit of the following harnesses
| ||
Disconnect CN112 of the BiCU (PCB16) and turn on the machine.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC995-01 | D | CPM setting error 1 |
Comparison of machine serial number (11 digits) and machine identification code. Details:
| ||
Machine serial number (11 digits) or machine identification code does not match. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC995-02 | D | CPM setting error 2 |
Comparison of machine serial number (11 digits) and machine identification code. Details: Machine serial number cannot be identified because of NV-RAM replacement or malfunctioning. | ||
Machine serial number (11 digits) or machine identification code does not match. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC995-03 | D | CPM setting error 3 |
Comparison of machine serial number (11 digits) and machine identification code. Details: Unable to recognize the machine identification code because the controller was replaced incorrectly or is malfunctioning. | ||
Machine serial number (11 digits) or machine identification code does not match. | ||
Replace it with a specified controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC995-04 | D | CPM setting error 4 |
Comparison of machine serial number (11 digits) and machine identification code. | ||
Machine serial number (11 digits) or machine identification code does not match. | ||
Return the parts to the original configuration, and then replace them according to the manual. |